Impact of Grid Impedance on LVRT Performance of DFIG System With Rotor Crowbar Technology
Open Access
- 29 August 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 127999-128008
Abstract
Nowadays, most of the doubly fed induction generators (DFIGs) are equipped with rotor crowbar for the requirement of low voltage ride through (LVRT). The crowbar resistance is an important parameter, and it is selected taking rotor overcurrent and dc link overvoltage limits into consideration. However, the impact of grid impedance on the LVRT performance of DFIG and crowbar resistance is not adequately researched. This paper proposed an improved method to analyze the LVRT performance of DFIG system with rotor crowbar taking the influence of the grid impedance to fill this gap. The impedance of the present grid would be decreased in the future due to the installation of more wind farms to the grid. As a consequence, the performance of DFIG under LVRT with rotor crowbar is degraded. So the design rules of the crowbar resistance need to be reconstructed. Additionally, the analytical expression of the crowbar resistance is derived considering the grid impedance. The effectiveness of the proposed method is validated through theoretical analysis and MATLAB simulations.Keywords
Funding Information
- National Natural Science Foundation of China (51577025)
- Zhejiang Key Research and Development Project (2017C01043)
This publication has 32 references indexed in Scilit:
- Feedforward Transient Compensation Control for DFIG Wind Turbines During Both Balanced and Unbalanced Grid DisturbancesIEEE Transactions on Industry Applications, 2013
- Power angle control of grid‐connected doubly fed induction generator wind turbines for fault ride‐throughIET Renewable Power Generation, 2013
- A novel adaptive control scheme for dynamic performance improvement of DFIG-Based wind turbinesEnergy, 2012
- Coordinated reactive power control for facilitating fault ride through of doubly fed induction generator- and fixed speed induction generator-based wind farmsIET Renewable Power Generation, 2010
- Advanced control of a doubly-fed induction generator for wind energy conversionElectric Power Systems Research, 2009
- An improved fault ride-through strategy for doubly fed induction generator-based wind turbinesIET Renewable Power Generation, 2008
- Double-fed induction generator control for variable speed wind power generationElectric Power Systems Research, 2006
- Ridethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage DipIEEE Transactions on Energy Conversion, 2005
- Control of Variable Speed Wind Turbines with Doubly-Fed Induction GeneratorsWind Engineering, 2004
- Doubly fed induction generator usingback-to-back PWM convertersand its application to variable-speed wind-energy generationIEE Proceedings - Electric Power Applications, 1996