Use of an intravascular T1 contrast agent to improve MR cine myocardial‐blood pool definition in man

Authors:

Abstract
The feasibility of improving myocardial/blood pool contrast in MR cine images through use of an intravascular contrast agent (Ferumoxtran, Advanced Magnetics, Inc., Cambridge, MA) was tested in four subjects. The contrast‐to‐noise ratio (CNR) demonstrated a trend toward improvement in the short axis and improved significantly in the long axis cine by an average of 128% (P < .05). Image intensity gradients at the myocardial/blood pool interface increased significantly in both the short and long axis (P < .01). It is expected that larger image intensity gradients at the endocardial border should improve the capabilities of automated segmentation algorithms, reducing the uncertainty and need for manual editing.

This publication has 15 references indexed in Scilit: