Inter-operator reliability and prediction bands of a novel protocol to measure the coordinated movements of shoulder-girdle and humerus in clinical settings
- 17 February 2009
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 47 (5) , 475-486
Abstract
A clinical motion analysis protocol was developed to measure the coordinated movements of shoulder-girdle and humerus (girdle-humeral rhythm—GD-H-R) during humerus flexion–extension (HFE) and ab-adduction (HAA), through an optoelectronic system. In particular, the protocol describes the GD-H-R with 2 angle–angle plots for each movement: girdle elevation–depression and protraction–retraction vs HFE, and vs HAA. Each of these plots is further divided in two subplots, one for the upward and one for the downward phases of the movement. By involving 11 participants and 2 operators, we measured the protocol’s inter-operator reliability which ranged from very-good to excellent depending on the angle–angle plot (median values of the inter-operator coefficient of multiple correlation for the angle–angle plots higher than 0.94). We then computed the subjects’ average control patterns, together with statistically meaningful prediction bands. ±1SD confidence bands were also computed and their width ranged from ±0.5° to ±4.6°. Based on these results we could conclude that the method is robust and able to identify even limited differences in the GD-H-R.Keywords
This publication has 32 references indexed in Scilit:
- The reliability of three-dimensional scapular attitudes in healthy people and people with shoulder impingement syndromeBMC Musculoskeletal Disorders, 2007
- Comparison between tripod and skin-fixed recording of scapular motionJournal of Biomechanics, 2007
- Repeatability of 3D gait kinematics obtained from an electromagnetic tracking system during treadmill locomotionJournal of Biomechanics, 2007
- Reliability of segmental accelerations measured using a new wireless gait analysis systemJournal of Biomechanics, 2006
- Soft tissue artefact assessment in humeral axial rotationGait & Posture, 2005
- Human movement analysis using stereophotogrammetryGait & Posture, 2005
- Effect of rotator cuff pathology on shoulder rhythmJournal of Shoulder and Elbow Surgery, 2005
- Quantifying Test-Retest Reliability Using the Intraclass Correlation Coefficient and the SEMJournal of Strength & Conditioning Research, 2005
- The bootstrap and its application in signal processingIEEE Signal Processing Magazine, 1998
- Repeatability of kinematic, kinetic, and electromyographic data in normal adult gaitJournal of Orthopaedic Research, 1989