Wirbelsäulenbelastung beim Sitzen auf einem Bürostuhl mit nach hinten kippbarer Rückenlehne / Loads Acting on the Spine when Seated on an Office Chair with a Tilting Back
Authors:
- A. RohlmannARA. Rohlmann
- H.-J. WilkeHWH.-J. Wilke
- F. GraichenFGF. Graichen
- G. BergmannGBG. Bergmann
- 1 January 2002
- journal article
- research article
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 47 (4) , 91-96
Abstract
Long periods of quiet sitting is considered a cause of low back pain. It is often assumed that spinal loads are high, especially when sitting erect. Modern office chairs with a tiltable back permit changes in the seated posture. In the most reclined position, some new chairs even match a kyphotic form of the lumbar spine. It is assumed that sitting on such a chair reduces low back pain. With the aim of determining spinal loading in different sitting positions, the loads acting on implanted fixation devices were measured telemetrically in two patients. Loads were measured in patients sitting on six different chairs with tiltable backs. In modern chairs, implant loading was always lower than while walking. In the end-tilt position of the chairback, loads were always lower than when the chairback was upright. Even when the lordotic curvature of the lumbar spine was "corrected", loads on the fixator were lower than when the subject was seated in the upright position. In a modern chair, spinal loading is no higher than with non-adjustable office chairs.Keywords
This publication has 12 references indexed in Scilit:
- Loads on an internal spinal fixation device during sittingJournal of Biomechanics, 2001
- Comparison of intradiscal pressures and spinal fixator loads for different body positions and exercisesErgonomics, 2001
- Intradiscal pressure together with anthropometric data – a data set for the validation of modelsClinical Biomechanics, 2001
- Monitoring In Vivo Implant Loads With a Telemeterized Internal Spinal Fixation DeviceSpine, 2000
- Loads on internal spinal fixators measured in different body positionsEuropean Spine Journal, 1999
- Loads on internal spinal fixation devicesDer Orthopäde, 1999
- Loads on an internal spinal fixation device during walkingJournal of Biomechanics, 1997
- Patient monitoring system for load measurement with spinal fixation devicesMedical Engineering & Physics, 1996
- Telemeterized Load Measurement Using Instrumented spinal Internal Fixators in a Patient With Degenerative InstabilitySpine, 1995
- An Improved Method of Stature Measurement for Quantitative Determination of Spinal LoadingSpine, 1992