Two-dimensional shear wave elastography and ultrasound-guided attenuation parameter for progressive non-alcoholic steatohepatitis
Authors:
Open Access
- 7 April 2021
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (4) , e0249493
Abstract
Background and aims: We investigated the usefulness of combining two-dimensional shear wave elastography and the ultrasound-guided attenuation parameter for assessing the risk of progressive non-alcoholic steatohepatitis, defined as non-alcoholic steatohepatitis with a non-alcoholic fatty liver disease activity score of ≥4 and a fibrosis stage of ≥2. Methods: This prospective study included 202 patients with non-alcoholic fatty liver disease who underwent two-dimensional shear wave elastography, ultrasound-guided attenuation parameter, vibration-controlled transient elastography, the controlled attenuation parameter, and liver biopsy on the same day. Patients were grouped according to liver stiffness measurement using two-dimensional shear wave elastography and the attenuation coefficient, assessed using the ultrasound-guided attenuation parameter: A, low liver stiffness measurement/low attenuation coefficient; B, low liver stiffness measurement/high attenuation coefficient; C, high liver stiffness measurement/low attenuation coefficient; and D, high liver stiffness measurement/high attenuation coefficient. Results: Two-dimensional shear wave elastography and vibration-controlled transient elastography had equivalent diagnostic performance for fibrosis. The areas under the curve of the ultrasound-guided attenuation parameter for identifying steatosis grades ≥S1, ≥S2, and S3 were 0.89, 0.91, and 0.92, respectively, which were significantly better than those of the controlled attenuation parameter (P<0.05). The percentages of progressive non-alcoholic steatohepatitis in Groups A, B, C, and D were 0.0%, 7.7%, 35.7%, and 50.0%, respectively (P<0.001). The prediction model was established as logit (p) = 0.5414 × liver stiffness measurement (kPa) + 7.791 × attenuation coefficient (dB/cm/MHz)—8.401, with area under the receiver operating characteristic curve, sensitivity, and specificity values of 0.832, 80.9%, and 74.6%, respectively; there was no significant difference from the FibroScan-aspartate aminotransferase score. Conclusion: Combined assessment by two-dimensional shear wave elastography and the ultrasound-guided attenuation parameter is useful for risk stratification of progressive non-alcoholic steatohepatitis and may be convenient for evaluating the necessity of specialist referral and liver biopsy.Keywords
Funding Information
- Japan Society for the Promotion of Science London (19K08400)
This publication has 37 references indexed in Scilit:
- Pathological Features of Fatty Liver DiseaseGastroenterology, 2014
- Magnetic resonance elastography predicts advanced fibrosis in patients with nonalcoholic fatty liver disease: A prospective studyHepatology, 2014
- Controlled attenuation parameter for the detection and quantification of hepatic steatosis in nonalcoholic fatty liver diseaseJournal of Gastroenterology and Hepatology, 2014
- Utility and appropriateness of the fatty liver inhibition of progression (FLIP) algorithm and steatosis, activity, and fibrosis (SAF) score in the evaluation of biopsies of nonalcoholic fatty liver diseaseHepatology, 2014
- Sample size estimation in diagnostic test studies of biomedical informaticsJournal of Biomedical Informatics, 2014
- Limitations of liver biopsy and non-invasive diagnostic tests for the diagnosis of nonalcoholic fatty liver disease/nonalcoholic steatohepatitisWorld Journal of Gastroenterology, 2014
- Nonalcoholic Fatty Liver Disease: Pathologic Patterns and Biopsy Evaluation in Clinical ResearchSeminars in Liver Disease, 2012
- Model for end-stage liver disease (MELD) and allocation of donor liversGastroenterology, 2003
- A model to predict poor survival in patients undergoing transjugular intrahepatic portosystemic shuntsHepatology, 2000
- Backscatter Coefficient Measurements Using a Reference Phantom to Extract Depth-Dependent Instrumentation FactorsUltrasonic Imaging, 1990