Bone response to orthodontic loading of endosseous implants in the rabbit calvaria: early continuous distalizing forces
Authors:
- M FinottiMFM Finotti
- F MiottiFMF Miotti
- Nn AldiniNANn Aldini
- G CordioliGCG Cordioli
Open Access
- 1 June 1999
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 21 (3) , 223-230
Abstract
The purpose of this experimental study was to evaluate the effect of early orthodontic loading on the stability and bone-implant interface of titanium implants in a rabbit model. Twenty-four short threaded titanium fixtures were inserted in the calvarial mid-sagittal suture of 10 rabbits. Two weeks following insertion, 20 implants (test group) were subjected to continuous distalization forces of 150 g for a period of 8 weeks. The remaining four implants (control group) were left unloaded for the same follow-up interval. Clinically, all implants except for one test fixture were stable, and exhibited no mobility or displacement throughout the experimental loading period. Histologically, all stable implants were well-integrated into bone. No differences could be found between the pressure and tension surfaces of the test implants relative to bone quality and density within a range of 1000 μm from the fixture surface. Similarly, qualitative differences were not observed between the apical and coronal portions of test fixtures. Morphometrically, a mean percentage bone-to-implant contact of 76.00 ± 18.73 per cent was found at the test pressure sides, 75.00 ± 11.54 per cent at the test tension sides, and 68.00 ± 15.55 per cent at the control unloaded surfaces. No statistically significant differences in the percentage of bone-to-metal contact length fraction were found between test pressure surfaces, test tension surfaces, and unloaded control surfaces. Marginal bone resorption around the implant collar or immediately beneath it was found in roughly the same percentage of analysed sites in the test and control fixtures. In contrast, slight bone apposition was demonstrated at the implant collar on the test pressure surfaces, while no apposition ro resorption were observed in the test tension zones. This study suggests that short endosseous implants can be used as anchoring units for orthodontic tooth movement early in the post-insertion healing period.Keywords
This publication has 11 references indexed in Scilit:
- Titanium implants and lateral forces. An experimental study with sheep.Clinical Oral Implants Research, 1997
- Orthodontic anchorage capacity of short titanium screw implants in the maxilla. An experimental study in the dog.Clinical Oral Implants Research, 1997
- The use of palatal implants for orthodontic anchorage. Design and clinical application of the orthosystem.Clinical Oral Implants Research, 1996
- Osseointegrated implants as orthodontic anchorage in the treatment of partially edentulous adult patientsEuropean Journal of Orthodontics, 1994
- Endosseous titanium implants during and after orthodontic load ‐ an experimental study in the dogClinical Oral Implants Research, 1993
- Titanium implant anchorage in orthodontic treatment: an experimental investigation in monkeysEuropean Journal of Orthodontics, 1990
- Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site.1990
- Rigid endosseous implants for orthodontic and orthopedic anchorage.1989
- Osseointegrated titanium implants for maxillofacial protraction in monkeysAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1988
- Orthodontic force application to titanium endosseous implants.1988