A Robust Method for Pulse Peak Determination in a Digital Volume Pulse Waveform With a Wandering Baseline
Authors:
- 3 February 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 8 (5) , 729-737
Abstract
This paper presents a robust method for pulse peak determination in a digital volume pulse (DVP) waveform with a wandering baseline. A proposed new method uses a modified morphological filter (MMF) to eliminate a wandering baseline signal of the DVP signal with minimum distortion and a slope sum function (SSF) with an adaptive thresholding scheme to detect pulse peaks from the baseline-removed DVP signal. Further in order to cope with over-detected and missed pulse peaks, knowledge based rules are applied as a postprocessor. The algorithm automatically adjusts detection parameters periodically to adapt to varying beat morphologies and fluctuations. Compared with conventional methods (highpass filtering, linear interpolation, cubic spline interpolation, and wavelet adaptive filtering), our method performs better in terms of the signal-to-error ratio, the computational burden (0.125 seconds for one minute of DVP signal analysis with the Intel Core 2 Quad processor @ 2.40 GHz PC), the true detection rate (97.32% with an acceptance level of 4 ms ) as well as the normalized error rate (0.18%). In addition, the proposed method can detect true positions of pulse peaks more accurately and becomes very useful for pulse transit time (PTT) and pulse rate variability (PRV) analyses.Keywords
Funding Information
- Ministry of Science, ICT & Future Planning (MSIP), Korea
- Information Technology Research Center (ITRC)
- National IT Industry Promotion Agency
This publication has 22 references indexed in Scilit:
- A Knowledge-Based Approach to Arterial Stiffness Estimation Using the Digital Volume PulseIEEE Transactions on Biomedical Circuits and Systems, 2012
- Removal of Pulse Waveform Baseline Drift Using Cubic Spline Interpolation2010 4th International Conference on Bioinformatics and Biomedical Engineering, 2010
- Adaptive threshold method for the peak detection of photoplethysmographic waveformComputers in Biology and Medicine, 2009
- A Comparison of Baseline Removal Algorithms for Electrocardiogram (ECG) Based Automated Diagnosis of Coronory Heart Disease2009
- Efficient and fast ECG baseline wander reduction without distortion of important clinical information2008
- ECG signal denoising and baseline wander correction based on the empirical mode decompositionComputers in Biology and Medicine, 2008
- A knowledge-based technique for automated detection of ischaemic episodes in long duration electrocardiogramsMedical & Biological Engineering & Computing, 2001
- Application of a wavelet adaptive filter to minimise distortion of the ST-segmentMedical & Biological Engineering & Computing, 1998
- Impulsive noise suppression and background normalization of electrocardiogram signals using morphological operatorsIEEE Transactions on Biomedical Engineering, 1989
- Electrocardiogram baseline noise estimation and removal using cubic splines and state-space computation techniquesComputers and Biomedical Research, 1977