Do optical sensor readings change throughout the day? An evaluation of two sensor systems
- 12 March 2020
- journal article
- research article
- Published by Taylor & Francis in Journal of Plant Nutrition
- Vol. 43 (11) , 1689-1696
Abstract
Optical sensors are useful tools for rapid and periodic assessment of plant nutritional status. However, the utility and potential of these sensors may be reduced if their readings change throughout the day. Therefore, this study aimed to assess the effects of time of day on measurements of the SPAD-502 chlorophyll meter and the GreenSeeker throughout the bean crop cycle. The treatments consisted of time of day for sensor measurements (8:00, 12:00, and 16:00 h) throughout six dates over the crop cycle. The results showed that measurements from the SPAD-502 and the GreenSeeker significantly changed according to time of day. The SPAD index at 16:00 h showed the lowest coefficient of variation (CV, 2.5%) and was on average, 3.05 ± 0.43, and 1.12 ± 0.25 SPAD units higher when compared to readings obtained at 8:00 and 12:00 h. Differently, the NDVI from the GreenSeeker showed the lowest CV (4.34%) at 8:00 h and was, on average, 0.06 ± 0.028 and 0.03 ± 0.01 units higher than measurements taken at 16:00 h and 12:00 h, respectively. Furthermore, the different times of sensor measurements present variations in air temperature and solar radiation, which directly influence the leaf water content and paraheliotropic movements. Thus, the indices from both sensors tend to show a high variability during different times of the day. Therefore, it is essential to create a consistent sampling protocol to reduce the variability of sensor measurements during the crop cycle.Keywords
This publication has 42 references indexed in Scilit:
- Prospects for Monitoring Cotton Crop Maturity with Normalized Difference Vegetation IndexAgronomy Journal, 2010
- Characterizing vegetation indices derived from active and passive sensorsInternational Journal of Remote Sensing, 2010
- Active Sensor Reflectance Measurements of Corn Nitrogen Status and Yield PotentialAgronomy Journal, 2008
- Using Relative Chlorophyll Meter Values to Determine Nitrogen Application Rates for CornAgronomy Journal, 2007
- Soil‐ and plant‐based nitrogen‐fertilizer recommendations in arable farmingJournal of Plant Nutrition and Soil Science, 2005
- Distortion of the SPAD 502 chlorophyll meter readings by changes in irradiance and leaf water statusAgronomy for Sustainable Development, 2004
- Chloroplast movements in the fieldPlant, Cell & Environment, 2003
- Factors that Affect the Quality and Quantity of Sunlight Reflected from Alfalfa CanopiesPlant Disease, 2001
- Effect of wetness on turfgrass canopy reflectanceAgricultural and Forest Meteorology, 2001
- Calibration of the Minolta SPAD-502 leaf chlorophyll meterPhotosynthesis Research, 1995