Evaluation of platelet count after isolated biological aortic valve replacement with Freedom Solo bioprosthesis
Open Access
- 1 June 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 41 (1) , 69-73
Abstract
The risk of thrombocytopenia in patients undergoing aortic valve replacement (AVR) with the Freedom Solo (FS) bioprosthesis is controversial. The aim of our study was to evaluate the postoperative evolution of platelet count and function after AVR in patients undergoing isolated biological AVR with FS. Between May 2005 and June 2010, 322 patients underwent isolated biological AVR. Of these, 116 patients received FS and were compared with 206 patients who received biological valves. Platelet count, mean platelet volume (MPV), and platelet distribution width (PDW) were evaluated at baseline (T0), first (T1), second (T2), and fifth (T3) postoperative days, respectively. Overall in-hospital mortality was 1.5% with no difference between the two groups. Thirty-seven (11.5%) patients developed thrombocytopenia. FS implantation was associated with a higher incidence of thrombocytopenia compared with the control group (24.1% vs 4.4%, p < 0.0001). Patients in the FS group showed a lower platelet count than the control group at T1 (99.4 ± 38 × 103 μl−1 vs 122.5 ± 41.6 × 103 μl−1, p < 0.001), T2 (79.7 ± 36.3 × 103 μl−1 vs 122.5 ± 43.3 × 103 μl−1, p < 0.001) and T3 (86.6 ± 57.4 × 103 μl−1 vs 158.4 ± 55.8 × 103 μl−1, p < 0.001). Moreover, the FS group also had a higher MPV (11.6 ± 0.9 fl vs 11 ± 1 fl, p < 0.001) and higher PDW (15.1 ± 2.3 fl vs 13.9 ± 2.1 fl, p < 0.001) at T3. In a multivariable analysis, FS (p < 0.0001), body surface area (p < 0.0001), cardiopulmonary bypass time (p = 0.003), and lower preoperative platelet counts (p = 0.006) were independent predictors of thrombocytopenia. The FS valve might increase the risk of thrombocytopenia and platelet activation, in the absence of adverse clinical events. Prospective randomized studies on platelet function need to confirm our data.Keywords
This publication has 23 references indexed in Scilit:
- Freedom SOLO valve: early- and intermediate-term results of a single centre's first 100 casesEuropean Journal of Cardio-Thoracic Surgery, 2011
- Thrombocytopenia After Freedom Solo: The Mystery Goes OnThe Annals of Thoracic Surgery, 2011
- Perioperative thrombocytopenia in cardiac surgical patients — incidence of heparin-induced thrombocytopenia, morbidities and mortalityEuropean Journal of Cardio-Thoracic Surgery, 2010
- Thrombocytopenia After Aortic Valve Replacement With Freedom Solo Bioprosthesis: A Propensity StudyThe Annals of Thoracic Surgery, 2010
- Invited CommentaryThe Annals of Thoracic Surgery, 2010
- Thrombocytopenia after Sorin Freedom Solo valve implantation: is there a clinical relevance?The Thoracic and Cardiovascular Surgeon, 2010
- Differences in the recovery of platelet counts after biological aortic valve replacementInteractive CardioVascular and Thoracic Surgery, 2008
- Thrombocytopenia after aortic valve replacement with the Freedom Solo stentless bioprosthesisInteractive CardioVascular and Thoracic Surgery, 2008
- Platelet activation after aortic prosthetic valve surgeryInteractive CardioVascular and Thoracic Surgery, 2005
- CryoLife-O'Brien Stentless Valve: 10-Year Results of 402 ImplantsThe Annals of Thoracic Surgery, 2005