Determination of Some Trace Metals in Environmental Samples by Flame AAS Following Solid Phase Extraction with Amberlite XAD‐2000 Resin after Complexing with 8‐Hydroxyquinoline
Authors:
- 7 February 2007
- journal article
- research article
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 25 (2) , 196-202
Abstract
A procedure for preconcentration of Mn(II), Fe(II), Co(II), Cu(II), Cd(II), Zn(II), Pb(II) and Ni(II) based on retention of their complexes with 8‐hydroxyquinoline (HQ) on Amberlite XAD‐2000 resin in a column was proposed for the analysis of environmental samples by flame AAS. Various parameters such as pH, eluent type, volume, concentration, flow rate and volume of sample solution, and matrix interference effect on the retention of the metal ions were investigated. The optimum pHs for the retention of metal complexes in question were about 6 except for Mn2+ for whose value is 8. The loading capacity of the adsorbent for these metals and their recoveries from the resin under the optimum conditions were in the range 6.82–9.26 mg·g−1 and 95%–101%, respectively. The enrichment factor was calculated as 100 and the limit of detection was in the range 0.3–2.2 µg·L−1 (n=20, blank+3s). The proposed enrichment method was applied to tap water, stream water and vegetable samples. The validation of the procedure was carried out by analysis of certified reference material and standard addition. The analytes were determined with a relative standard deviation lower than 6% in all samples.Keywords
This publication has 37 references indexed in Scilit:
- Evaluation of commercial C18 cartridges for trace elements solid phase extraction from seawater followed by inductively coupled plasma-optical emission spectrometry determinationAnalytica Chimica Acta, 2005
- Column Solid-Phase Extraction with 2-Acetylmercaptophenyldiazoaminoazobenzene (AMPDAA) Impregnated Amberlite XAD-4 and Determination of Trace Heavy Metals in Natural Waters by Flame Atomic Absorption SpectrometryMicrochimica Acta, 2004
- Solid-Phase Extraction and Spectrophotometric Determination of Molybdenum(VI) in Soil and Plant Samples as a Mo(V)-Thiocyanate ComplexMicrochimica Acta, 2004
- Metal Sorption, Solid Phase Extraction and Preconcentration Properties of Two Silica Gel Phases Chemically Modified with 2-Hydroxy-1-NaphthaldehydeMicrochimica Acta, 2003
- Preconcentration of manganese(II) from natural and sea water on a palmitoyl quinolin-8-ol functionalized XAD copolymer resin and spectrophotometric determination with the formaldoxime reagentAnalytica Chimica Acta, 2003
- Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometryAnalytica Chimica Acta, 2002
- Adsorption of FeCl3, CuCl2 and ZnCl2 on silsesquioxane 3-n-propylpyridiniumchloride polymer film adsorbed on Al2O3 coated silica gelColloids and Surfaces A: Physicochemical and Engineering Aspects, 2001
- On-line preconcentration system for lanthanum determination in urine using FI–ICP-AESAnalytica Chimica Acta, 1998
- Determination of selenium speciation in river waters by adsorption on iron(III)-Chelex-100 resin and differential pulse cathodic stripping voltammetryAnalytica Chimica Acta, 1996
- On-line preconcentration system for inductively coupled plasma atomic emission spectrometry with quinolin-8-ol and Amberlite XAD-2 resinAnalytica Chimica Acta, 1992