Compensation of breathing motion artifacts for MRI with continuously moving table
- 25 February 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (3) , 701-712
Abstract
Breathing motion is one of the main sources of artifacts in MRI acquisitions that can severely impair diagnosis. In MRI with continuously moving table, the application of common motion compensation approaches such as breath holding or the synchronization of the measurement with the breathing motion can be problematic. In this study, a technique for the reduction of breathing‐motion artifacts for MRI with continuously moving table is presented, which reconstructs motion‐consistent volumes from data acquired during free breathing. Axial images are acquired rapidly compared to the period of the breathing motion and consistently combined using a combination of rigid and nonrigid slice‐to‐volume registration. This new technique is compared to a previously reported artifact reduction method for MRI with continuously moving table that is based on the same acquisition scheme. While the latter method only suppresses ghosting artifacts, the new technique is shown to additionally reduce blurring, misregistrations, and signal cancellations in the reconstructed images. Magn Reson Med 63:701–712, 2010.Keywords
This publication has 41 references indexed in Scilit:
- Respiratory motion‐compensated radial dynamic contrast‐enhanced (DCE)‐MRI of chest and abdominal lesionsMagnetic Resonance in Medicine, 2008
- Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free‐breathing MRIMagnetic Resonance in Medicine, 2008
- Generalized MRI reconstruction including elastic physiological motion and coil sensitivity encodingMagnetic Resonance in Medicine, 2008
- Prospective correction of affine motion for arbitrary MR sequences on a clinical scannerMagnetic Resonance in Medicine, 2005
- Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imagingMagnetic Resonance in Medicine, 1999
- Total-body MR imaging in as little as 18 seconds.Radiology, 1997
- A respiratory motion artifact reduction method in magnetic resonance imaging of the chestIEEE Transactions on Medical Imaging, 1991
- Respiration Artifacts in MR ImagingJournal of Computer Assisted Tomography, 1986
- Respiratory Ordered Phase Encoding (ROPE)Journal of Computer Assisted Tomography, 1985
- Magnetic resonance imaging with respiratory gating: techniques and advantagesAmerican Journal of Roentgenology, 1984