Higher HbA1c Measurement Quality Standards are Needed for Follow-Up and Diagnosis: Experience and Analyses from Germany
- 14 September 2018
- journal article
- research article
- Published by Georg Thieme Verlag KG in Hormone and Metabolic Research
- Vol. 50 (10) , 728-734
Abstract
Measurement of HbA1c is an essential laboratory measure for the follow-up and therapy decision-making in patients with diabetes. HbA1c is one of the measurands in laboratory medicine that have to be successfully checked according to the criteria of the guidelines of the German Medical Association (Rili-BAEK) in external quality assurance using the reference method value concept, when applied in patient care. The allowed deviation of ±18% in external quality assessment (EQA) and ± 10% in internal quality control has been ultimately met by virtually all the different manufacturers and methods. However, such broad limits for permissible deviations are not suitable in view of medical requirements in patient care. The low-level acceptance criteria also depends on the previously used EQA materials used in Germany. In fact, HbA1c measurement results that are imprecisely measured or come from incorrectly calibrated devices are difficult to identify. With implementation of unprocessed fresh EDTA blood, the situation has changed. Until now systems with unit use reagents for point-of-care testing (POCT) of HbA1c are not mandatory to participate in EQA schemes in Germany. This paper outlines why there was a need to narrow the acceptance limits listed within the Rili-BAEK for HbA1c’s internal (to ± 3%) and external (to ± 8%) quality controls in EQA schemes for Germany, which will take place after a transition period in the next years. Higher quality in HbA1c measurements will help to avoid misdiagnosis of diabetes as well as potential over- or undertreatment of patients at risk for diabetes.Keywords
This publication has 20 references indexed in Scilit:
- HbA1c for diagnosis of type 2 diabetes. Is there an optimal cut point to assess high risk of diabetes complications, and how well does the 6.5% cutoff perform?Diabetes, Metabolic Syndrome and Obesity, 2013
- HbA1c – ein Alleskönner?Der Diabetologe, 2011
- Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes MellitusDiabetes Care, 2011
- Hemoglobin A1c and glucose criteria identify different subjects as having type 2 diabetes in middle-aged and older populations: The KORA S4/F4 StudyAnnals of Medicine, 2010
- Pitfalls in the use of HbA1c as a diagnostic test: the ethnic conundrumNature Reviews Endocrinology, 2010
- Hemoglobin A1c and Fructosamine for Assessing Glycemic Control in Diabetic Patients With CKD Stages 3 and 4American Journal of Kidney Diseases, 2010
- International Expert Committee Report on the Role of the A1C Assay in the Diagnosis of DiabetesDiabetes Care, 2009
- Red cell life span heterogeneity in hematologically normal people is sufficient to alter HbA1cBlood, 2008
- Investigation of the effect of poorly controlled diabetes mellitus on erythrocyte lifeJournal of Diabetes and its Complications, 1995
- Long-Term Complications of Diabetes MellitusThe New England journal of medicine, 1993