Implantation of contemporary transcatheter aortic valves in small aortic annuli: the international multicentre TAVI-SMALL 2 registry
Authors:
- 1 June 2023
- journal article
- research article
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 19 (3) , 256-266
Abstract
Treatment of aortic stenosis in patients with small annuli is challenging and can result in prosthesis-patient mismatch (PPM). We aimed to compare the forward flow haemodynamics and clinical outcomes of contemporary transcatheter valves in patients with small annuli. The TAVI-SMALL 2 international retrospective registry included 1,378 patients with severe aortic stenosis and small annuli (annular perimeter 2) treated with transfemoral self-expanding (SEV; n=1,092) and balloon-expandable valves (BEV; n=286) in 16 high-volume centres between 2011 and 2020. Analyses comparing SEV versus BEV and supra-annular (SAV; n=920) versus intra-annular valves (IAV; n=458) included inverse probability of treatment weighting (IPTW). The primary endpoints were the predischarge mean aortic gradient and incidence of severe PPM. The secondary endpoint was the incidence of more than mild paravalvular leak (PVL). The predischarge mean aortic gradient was lower after SAV versus IAV (7.8±3.9 vs 12.0±5.1; p<0.001) and SEV versus BEV implantation (8.0±4.1 vs 13.6±4.7; p<0.001). Severe PPM was more common with IAV and BEV when compared to SAV and SEV implantation, respectively, (8.8% vs 3.6%; p=0.007 and 8.7% vs 4.6%; p=0.041). At multivariable logistic regression weighted by IPTW, SAV protected from severe PPM regardless of its definition. More than mild PVL occurred more often with SEV versus BEV (11.6% vs 2.6%; p<0.001). In small aortic annuli, implantation of SAV and SEV was associated with a more favourable forward haemodynamic profile than after IAV and BEV implantation, respectively. More than mild PVL was more common after SEV than BEV implantation.Keywords
This publication has 29 references indexed in Scilit:
- Short-Term Outcome and Hemodynamic Performance of Next-Generation Self-Expanding Versus Balloon-Expandable Transcatheter Aortic Valves in Patients With Small Aortic AnnulusCirculation: Cardiovascular Interventions, 2017
- Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve ReplacementJACC: Cardiovascular Imaging, 2016
- Usefulness of Predilation Before Transcatheter Aortic Valve ImplantationThe American Journal of Cardiology, 2016
- Prosthesis–Patient Mismatch After Transcatheter Aortic Valve ImplantationThe Annals of Thoracic Surgery, 2016
- Moving towards best practice when using inverse probability of treatment weighting (IPTW) using the propensity score to estimate causal treatment effects in observational studiesStatistics in Medicine, 2015
- Impact of Aortic Annulus Size on Valve Hemodynamics and Clinical Outcomes After Transcatheter and Surgical Aortic Valve ReplacementCirculation: Cardiovascular Interventions, 2014
- Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve ReplacementCirculation, 2013
- Incidence and impact of prosthesis-patient mismatch after transcatheter aortic valve implantation.2013
- Doubly Robust Estimation of Causal EffectsAmerican Journal of Epidemiology, 2011
- The problem of valve prosthesis-patient mismatch.Circulation, 1978