Virtual Non-Contrast Reconstructions of Photon-Counting Detector CT Angiography Datasets as Substitutes for True Non-Contrast Acquisitions in Patients after EVAR—Performance of a Novel Calcium-Preserving Reconstruction Algorithm
Authors:
- Josua A. DeckerJDJosua A. Decker
- Stefanie BetteSBStefanie Bette
- Christian Scheurig-MuenklerCSChristian Scheurig-Muenkler
- Bertram JehsBJBertram Jehs
- Franka RischFRFranka Risch
- Piotr WoźnickiPWPiotr Woźnicki
- Franziska M. BraunFBFranziska M. Braun
- Mark HaertingMHMark Haerting
- Claudia WollnyCWClaudia Wollny
- Thomas J. KroenckeTKThomas J. Kroencke
- Florian SchwarzFSFlorian Schwarz
Open Access
- 22 February 2022
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 12 (3) , 558
Abstract
The purpose of this study was to evaluate virtual-non contrast reconstructions of Photon-Counting Detector (PCD) CT-angiography datasets using a novel calcium-preserving algorithm (VNCPC) vs. the standard algorithm (VNCConv) for their potential to replace unenhanced acquisitions (TNC) in patients after endovascular aneurysm repair (EVAR). 20 EVAR patients who had undergone CTA (unenhanced and arterial phase) on a novel PCD-CT were included. VNCConv- and VNCPC-series were derived from CTA-datasets and intraluminal signal and noise compared. Three readers evaluated image quality, contrast removal, and removal of calcifications/stent parts and assessed all VNC-series for their suitability to replace TNC-series. Image noise was higher in VNC- than in TNC-series (18.6 ± 5.3 HU, 16.7 ± 7.1 HU, and 14.9 ± 7.1 HU for VNCConv-, VNCPC-, and TNC-series, p = 0.006). Subjective image quality was substantially higher in VNCPC- than VNCConv-series (4.2 ± 0.9 vs. 2.5 ± 0.6; p < 0.001). Aortic contrast removal was complete in all VNC-series. Unlike in VNCConv-reconstructions, only minuscule parts of stents or calcifications were erroneously subtracted in VNCPC-reconstructions. Readers considered 95% of VNCPC-series fully or mostly suited to replace TNC-series; for VNCConv-reconstructions, however, only 75% were considered mostly (and none fully) suited for TNC-replacement. VNCPC-reconstructions of PCD-CT-angiography datasets have excellent image quality with complete contrast removal and only minimal erroneous subtractions of stent parts/calcifications. They could replace TNC-series in almost all cases.Keywords
This publication has 30 references indexed in Scilit:
- Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repairLa radiologia medica, 2014
- Dual-energy computed tomography after endovascular aortic aneurysm repair: The role of hard plaque imaging for endoleak detectionEuropean Radiology, 2014
- Comparison of outcomes following endovascular repair of abdominal aortic aneurysms based on size thresholdJournal of Vascular Surgery, 2013
- Quantification of Coronary Artery Calcium on the Basis of Dual-Energy Coronary CT AngiographyRadiology, 2012
- Virtual non-contrast in second-generation, dual-energy computed tomography: Reliability of attenuation valuesEuropean Journal of Radiology, 2012
- Image Quality of Virtual Noncontrast Images Derived from Dual-energy CT Angiography after Endovascular Aneurysm RepairJournal of Vascular and Interventional Radiology, 2010
- Estimating risk associated with radiation exposure during follow-up after endovascular aortic repair (EVAR).2010
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Secondary interventions following endovascular abdominal aortic aneurysm repair using current endografts. A EUROSTAR reportJournal of Vascular Surgery, 2006
- Estimation of Cancer Mortality Associated with Repetitive Computed Tomography ScanningAmerican Journal of Respiratory and Critical Care Medicine, 2006