Abstract
Purpose Thyroid-associated ophthalmopathy (TAO) might lead to blindness and orbital deformity. The early diagnosis and treatment are conducive to control disease progression, but currently, there is no effective screening method. The present study aimed to introduce an artificial intelligence (AI) model for screening and testing the model with TAO patients under clinical conditions. Methods A total of 1435 computed tomography (CT) scans were obtained from the hospital. These CT scans were preprocessed by resampling and extracting the region of interest. CT from 193 TAO patients and 715 healthy individuals were adopted for three-dimensional (3D)-ResNet model training, and 49 TAO patients and 178 healthy people were adopted for external verification. Data from 150 TAO patients and 150 healthy people were utilized for application tests under clinical conditions, including non-inferiority experiments and diagnostic tests, respectively. Results In the external verification of the model, the area under the receiver operating characteristic (ROC) curve (AUC) was 0.919, indicating a satisfactory classification effect. The accuracy, sensitivity, and specificity were 0.87, 088, and 0.85, respectively. In non-inferiority experiments: the accuracy was 85.67% in the AI group and 84.33% in the resident group. The model passed both non-inferiority experiments (p = 0.001) and diagnostic test (the AI group sensitivity = 0.87 and specificity = 0.84%). Conclusions A promising orbital CT-based TAO screening AI model was established and passed application tests under clinical conditions. This may provide a new TAO screening tool with further validation.Keywords
Funding Information
- National Key R&D Program of China (2018YFC1106100, 2018YFC1106101)
- Interdisciplinary Program of Shanghai Jiao Tong University (ZH2018QNA07, ZH2018ZDA12)
- The Science and Technology Commission of Shanghai (19410761100, 19DZ2331400)
This publication has 25 references indexed in Scilit:
- Quantitative analysis of orbital soft tissues on computed tomography to assess the activity of thyroid-associated orbitopathyGraefe's Archive for Clinical and Experimental Ophthalmology, 2016
- The 2016 European Thyroid Association/European Group on Graves' Orbitopathy Guidelines for the Management of Graves' OrbitopathyEuropean Thyroid Journal, 2016
- STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy StudiesRadiology, 2015
- Usefulness of the ratio of orbital fat to total orbit area in mild-to-moderate thyroid-associated ophthalmopathyBritish Journal of Radiology, 2015
- Disease Activity in Graves' Ophthalmopathy: Diagnosis with Orbital MR Imaging and Correlation with Clinical ScoreThe Neuroradiology Journal, 2013
- The Design of SimpleITKFrontiers in Neuroinformatics, 2013
- Prevention of Graves’ ophthalmopathyBest Practice & Research Clinical Endocrinology & Metabolism, 2012
- Graves’ Orbitopathy: Extraocular Muscle/Total Orbit Area Ratio is Positively Related to the Clinical Activity ScoreEuropean Journal of Ophthalmology, 2011
- Graves' OphthalmopathyNew England Journal of Medicine, 2010
- Signal intensity, clinical activity and cross-sectional areas on MRI scans in thyroid eye diseaseEuropean Journal of Radiology, 2005