Radiation dosimetry assessment of routine CT scanning protocols used in Western Australia
Authors:
- Rachael E MoorinRMRachael E Moorin
- Rene ForsythRFRene Forsyth
- David J GibsonDGDavid J Gibson
- Richard FoxRFRichard Fox
- 1 March 2013
- journal article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 33 (2) , 295-312
Abstract
Technical data on local CT practice in Western Australia were collected for five major CT providers using a self-completed questionnaire. The CTDIvol DLP and effective dose for each protocol were obtained and providers were ranked according to radiation burden for each clinical scenario. The mean, median, 75th percentile and standard deviation were calculated for both effective dose and DLP for each scenario and these values were compared with published data. CT utilisation data were used to estimate the attributable radiation dose to the WA population and the potential change in population annual effective dose according to the protocol used was estimated. We found that wide variations in technique and radiation dose exist across providers for similar examinations, producing a higher radiation burden than reported internationally. As expected, the CT protocol used dramatically affects the radiation dose received, and this has a significant effect on annual population dose. This study highlights the need for recognition and understanding of both the degree of variation in radiation dose across providers and the relatively high radiation burden afforded by protocols in use in Western Australia so that necessary dialogue can be launched for practitioner consensus on appropriate diagnostic reference levels in CT scanning.Keywords
This publication has 15 references indexed in Scilit:
- Survey of computed tomography technique and radiation dose in Sudanese hospitalsEuropean Journal of Radiology, 2011
- Towards establishment of the national reference dose levels from computed tomography examinations in TanzaniaJournal of Radiological Protection, 2006
- Implementation of DRLs in the UKRadiation Protection Dosimetry, 2005
- Survey of computed tomography techniques and absorbed dose in Italian hospitals: a comparison between two methods to estimate the dose–length product and the effective dose and to verify fulfilment of the diagnostic reference levelsEuropean Radiology, 2005
- Radiation Exposure at Chest CT: A Statement of the Fleischner SocietyRadiology, 2003
- A survey of 14 computed tomography scanners in Greece and 32 scanners in Italy. Examination frequencies, dose reference values, effective doses and doses to organs.Radiation Protection Dosimetry, 2003
- Radiation dose in CT: are we meeting the challenge?British Journal of Radiology, 2002
- Is computed tomography of the body overused? An audit of 2068 attendances in a large acute hospitalBritish Journal of Radiology, 1996
- The Increasing Importance of X Ray Computed Tomography as a Source of Medical ExposureRadiation Protection Dosimetry, 1995
- Is there a Sisyphus Syndrome in Health Care?1992