Optimization of spiral‐based pulse sequences for first‐pass myocardial perfusion imaging
Open Access
- 10 January 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 65 (6) , 1602-1610
Abstract
Although spiral trajectories have multiple attractive features such as their isotropic resolution, acquisition efficiency, and robustness to motion, there has been limited application of these techniques to first‐pass perfusion imaging because of potential off‐resonance and inconsistent data artifacts. Spiral trajectories may also be less sensitive to dark‐rim artifacts that are caused, at least in part, by cardiac motion. By careful consideration of the spiral trajectory readout duration, flip angle strategy, and image reconstruction strategy, spiral artifacts can be abated to create high‐quality first‐pass myocardial perfusion images with high signal‐to‐noise ratio. The goal of this article was to design interleaved spiral pulse sequences for first‐pass myocardial perfusion imaging and to evaluate them clinically for image quality and the presence of dark‐rim, blurring, and dropout artifacts. Magn Reson Med, 2011.Keywords
Funding Information
- AHA (10SDG2650038)
- NIH (5T32EB003841, R01 HL079110)
- Siemens Medical Solutions
This publication has 27 references indexed in Scilit:
- Low Diagnostic Yield of Elective Coronary AngiographyNew England Journal of Medicine, 2010
- Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradientsMagnetic Resonance in Medicine, 2008
- Measurement of myocardial frequency offsets during first pass of a gadolinium‐based contrast agent in perfusion studiesMagnetic Resonance in Medicine, 2008
- Semiautomatic off‐resonance correction in spiral imagingMagnetic Resonance in Medicine, 2008
- Three dimensional first-pass myocardial perfusion imaging at 3T: feasibility studyJournal of Cardiovascular Magnetic Resonance, 2008
- Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the artJournal of Cardiovascular Magnetic Resonance, 2008
- Fast automatic linear off-resonance correction method for spiral imagingMagnetic Resonance in Medicine, 2006
- Multislice first‐pass myocardial perfusion imaging: Comparison of saturation recovery (SR)‐TrueFISP‐two‐dimensional (2D) and SR‐TurboFLASH‐2D pulse sequencesJournal of Magnetic Resonance Imaging, 2004
- Extended coverage first‐pass perfusion imaging using slice‐interleaved TSENSEMagnetic Resonance in Medicine, 2003
- Dynamic contrast‐enhanced myocardial perfusion imaging using saturation‐prepared TrueFISPJournal of Magnetic Resonance Imaging, 2002