The Evaluation of Analytical Performance of Immunoassay Tests by Using Six-Sigma Method
Authors:
Open Access
- 28 August 2017
- journal article
- research article
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Journal of Medical Biochemistry
- Vol. 36 (4) , 301-308
Abstract
Summary: Background: The Six-Sigma Methodology is a quality measurement method in order to evaluate the performance of the laboratory. In the present study, it is aimed to evaluate the analytical performance of our laboratory by using the internal quality control data of immunoassay tests and by calculating process sigma values. Methods: Biological variation database (BVD) are used for Total Allowable Error (TEa). Sigma values were determined from coefficient of variation (CV) and bias resulting from Internal Quality Control (IQC) results for 3 subsequent months. If the sigma values are ≥6, between 3 and 6, and 6 was found for TPSA and TSH for the both levels of IQC for 3 months. When the sigma values were analyzed by calculating the mean of 3 months, folate, LH, PRL, TPSA, TSH and vitamin B12 were found >6. The mean sigma values of CA125, CA15-3, CA19-9, CEA, cortisol, ferritin, FSH, FT3, PTH and testosteron were >3 for 3-months. However, AFP, CA125 and FT4 produced sigma values <3 for varied months. Conclusion: When the analytical performance was evaluated according to Six-Sigma levels, it was generally found as good. It is possible to determine the test with high error probability by evaluating the fine sigma levels and the tests that must be quarded by a stringent quality control regime. In clinical chemistry laboratories, an appropriate quality control scheduling should be done for each test by using Six-Sigma Methodology.Keywords
This publication has 13 references indexed in Scilit:
- Application of sigma metrics for the assessment of quality assurance using the MQ-2000 PT HbA1c analyzerBiochemia Medica, 2015
- Assessing quality on the Sigma scale from proficiency testing and external quality assessment surveysClinical Chemistry and Laboratory Medicine (CCLM), 2015
- Sigma metrics used to assess analytical quality of clinical chemistry assays: importance of the allowable total error (TEa) targetClinical Chemistry and Laboratory Medicine (CCLM), 2014
- Practical application of Sigma Metrics QC procedures in clinical chemistryClinical Chemistry and Laboratory Medicine (CCLM), 2011
- Application of Sigma Metrics for the Assessment of Quality Assurance in Clinical Biochemistry Laboratory in India: A Pilot StudyIndian Journal of Clinical Biochemistry, 2010
- Quality Control Validation, Application of Sigma Metrics, and Performance Comparison between Two Biochemistry Analyzers in a Commercial Veterinary LaboratoryJournal of Veterinary Diagnostic Investigation, 2008
- Errors in a Stat Laboratory: Types and Frequencies 10 Years LaterClinical Chemistry, 2007
- Six Sigma and laboratory consultationClinical Chemistry and Laboratory Medicine (CCLM), 2007
- Application of the Six Sigma concept in clinical laboratories: a reviewClinical Chemistry and Laboratory Medicine (CCLM), 2007
- Current databases on biological variation: pros, cons and progressScandinavian Journal of Clinical and Laboratory Investigation, 1999