Abstract
Research has shown that it is possible for currents to flow in a broken rotor bar of a squirrel cage induction motor by means of interbar currents. Such research dealt only with single-cage motors. Further work was necessary when considering double-cage motors. This paper proves theoretically and experimentally that interbar currents also exist in double-cage motors. The influence of interbar currents on the current distribution around the broken bar is also shown.Keywords
This publication has 5 references indexed in Scilit:
- Steady-state analysis of double-cage induction motors with rotor-cage faultsIEE Proceedings B Electric Power Applications, 1987
- The Existence of Large Inter-Bar Currents in Three Phase Squirrel Cage Motors with Rotor-Bar And/Or End-Ring FaultsIEEE Transactions on Power Apparatus and Systems, 1984
- Steady-state analysis of 3-phase cage motors with rotor-bar and end-ring faultsIEE Proceedings B Electric Power Applications, 1982
- Origins of load losses in induction motors with cast aluminium rotorsProceedings of the Institution of Electrical Engineers, 1965
- Defining the Equivalent Circuit of the Double-Cage Motor [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1953