DC-Link Voltage Disturbance Rejection Strategy of PWM Rectifiers Based on Reduced-Order LESO
Authors:
Open Access
- 11 July 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 103693-103705
Abstract
In applications of pulse-width modulation (PWM) rectifiers, the high quality of the DC power is required. The fluctuation of grid voltage and the switching of equipment connected to the DC supply are likely to cause a sudden change in the DC-link voltage, resulting in equipment instability or even damage. Considering the bandwidth of the closed-loop current dynamic, this paper presents a novel DC-link voltage control strategy of PWM rectifiers based on the reduced-order linear extended state observer (RLESO). Using a first-order RLESO to observe and even compensate the model variations caused by grid voltage and DC-link voltage fluctuations or load transients, the proposed method can effectively improve the dynamic performance against grid and load disturbances, as well as for sudden changes in DC-link reference voltage. Combined with frequency domain analysis, this paper theoretically analyzes the sensitivity, stability, and tracking performance of the proposed method, providing a basis for the selection of controller parameters. And finally, simulation and experimental results are presented to demonstrate its validity and the superiority over the traditional PI control strategy.Keywords
Funding Information
- Science and Technology Planning Project of Guangdong Province (2016B090911003)
- Fundamental Research Funds for the Central Universities (2018KZ05)
This publication has 20 references indexed in Scilit:
- An Enhanced State Observer for DC-Link Voltage Control of Three-Phase AC/DC ConvertersIEEE Transactions on Power Electronics, 2017
- An Improved Control Strategy of Three-Phase PWM Rectifiers Under Input Voltage Distortions and DC-Offset Measurement ErrorsIEEE Journal of Emerging and Selected Topics in Power Electronics, 2017
- A new control scheme to improve load transient response of single phase PWM rectifier with Auxiliary Current Injection Circuit2016
- Adaptive ac filter parameters identification for voltage-oriented control of three-phase voltage-source rectifiersInternational Journal of Modelling, Identification and Control, 2015
- Vector control of three-phase voltage source PWM rectifier based on fractional-order controller2014
- Robust Model Predictive Current Control of Three-Phase Voltage Source PWM Rectifier With Online Disturbance ObservationIEEE Transactions on Industrial Informatics, 2012
- Design and analysis of a feedforward control scheme for a three-phase voltage source pulse width modulation rectifier using sensorless load current signalIET Power Electronics, 2009
- PWM regenerative rectifiers: state of the artIEEE Transactions on Industrial Electronics, 2005
- A review of single-phase improved power quality ac~dc convertersIEEE Transactions on Industrial Electronics, 2003
- Current control techniques for three-phase voltage-source PWM converters: a surveyIEEE Transactions on Industrial Electronics, 1998