Influencing Factors of the Induced Voltage in Signal Cable of Electrified Railway
Authors:
- Baoguo ShenBSBaoguo Shen
- Tiecheng LuTLTiecheng Lu
- Jingqian WangJWJingqian Wang
- Zhaokang LiuZLZhaokang Liu
- 1 March 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21574839,p. 1-4
Abstract
This paper built a model of tractive power supply system, analysed the influence on signal cables due to tractive power supply system through the software ATP-EMTP and found out influencing factors of the induced voltage in signal cable core of railway system. Simulation shows that: Structure and size of signal cable, earthing methods and earth resistance of the signal cable sheath are three of the most important factors. There are several ways to reduce the induced voltage in signal cable core, such as reduce the earth resistance of cable sheath and increase the number of earthing contacts of cable sheath.Keywords
This publication has 3 references indexed in Scilit:
- Inductive interference caused to telecommunication cables by nearby AC electric traction lines. Measurements and FEM calculationsIEEE Transactions on Power Delivery, 1999
- Measurements and Computations of Fault Current Distribution on Overhead Transmission LinesIEEE Transactions on Power Apparatus and Systems, 1984
- Ground Fault Current Distribution Between Soil and Neutral ConductorsIEEE Transactions on Power Apparatus and Systems, 1980