Reduction of the domino effect in osteoporotic vertebral compression fractures through short-segment fixation with intravertebral expandable pillars compared to percutaneous kyphoplasty: a case control study
Open Access
- 2 March 2013
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 14 (1) , 75
Abstract
Background: Osteoporotic vertebral compression fracture is the leading cause of disability and morbidity in elderly people. Treatment of this condition remains a challenge. Osteoporotic vertebral compression fractures can be managed with various approaches, but each has limitations. In this study, we compared the clinical outcomes obtained using short-segment fixation with intravertebral expandable pillars (I-VEP) to those obtained with percutaneous kyphoplasty in patients who had suffered vertebral compression fractures. Methods: The study included 46 patients with single-level osteoporotic thoracolumbar fractures. Twenty-two patients in Group I underwent short-segment fixation with I-VEP and 24 patients in Group II underwent kyphoplasty. All patients were evaluated pre- and postoperatively using a visual analogue scale, anterior height of the fractured vertebra, and kyphotic angle of the fractured vertebra. The latter 2 radiological parameters were measured at the adjacent segments as well. Results: There was no significant difference between the groups in terms of gender or fracture level, but the mean age was greater in Group II patients (p = 0.008). At the 1-year follow-up, there were no significant differences in the visual analogue scale scores, anterior height of the fractured vertebra, or the value representing anterior height above the fractured vertebra and kyphotic angle below the fractured vertebra, after adjusting for the patients’ gender, fracture level, and age. When considered separately, the anterior height below the fractured vertebra was significantly higher and the kyphotic angle above the fractured vertebra was significantly smaller in Group I than in Group II (p = 0.029 and p = 0.008, respectively). The kyphotic angle of the fractured vertebra was significantly smaller in Group II than in Group I (p < 0.001). Conclusions: In older individuals with vertebral compression fractures, kyphoplasty restored and maintained the collapsed vertebral body with less kyphotic deformity than that induced by short-segment fixation with I-VEP. Short-segment fixation with I-VEP was more effective in maintaining the integrity of adjacent segments, which prevented the domino effect often observed in patients with osteoporotic kyphotic spines.Keywords
This publication has 29 references indexed in Scilit:
- Initial clinical experience with a novel vertebral augmentation system for treatment of symptomatic vertebral compression fractures: A case series of 26 consecutive patientsBMC Musculoskeletal Disorders, 2011
- Role of the supine lateral radiograph of the spine in vertebroplasty for osteoporotic vertebral compression fracture: a prospective studyBMC Musculoskeletal Disorders, 2010
- Transpedicular Bone Grafting Following Short-Segment Posterior Instrumentation for Acute Thoracolumbar Burst FractureOrthopedics, 2009
- Proximal Junctional Kyphosis in Adult Spinal Deformity After Segmental Posterior Spinal Instrumentation and FusionSpine, 2008
- Revision strategies for complications and failure of vertebroplastiesEuropean Spine Journal, 2008
- Variation of the mechanical properties of PMMA to suit osteoporotic cancellous boneJournal of Biomaterials Science, Polymer Edition, 2008
- INvestigational Vertebroplasty Efficacy and Safety Trial (INVEST): a randomized controlled trial of percutaneous vertebroplastyBMC Musculoskeletal Disorders, 2007
- Combined Extraforaminal and Intradiscal Cement Leakage Following Percutaneous VertebroplastySpine, 2007
- Transpedicle body augmenter in painful osteoporotic compression fracturesEuropean Spine Journal, 2006
- Effects of Anterior Vertebral Grafting on the Traumatized Lumbar Spine After Pedicle Screw-Plate FixationSpine, 1993