Left Ventricular Assist Device as a Bridge to Recovery: Single Center Experience of Successful Device Explantation
- 20 September 2021
- journal article
- research article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (6) , 822-828
Abstract
Continuous-flow left ventricular assist devices (CF-LVAD) have been shown to enhance reverse remodeling and myocardial recovery in certain patients allowing for device removal. We sought to analyze the characteristics and describe outcomes of patients who underwent CF-LVAD explantation at a large academic center. We retrospectively identified all patients who underwent CF-LVAD explants due to recovery from 2006 to 2019. Patient baseline characteristics and data on pre- and postexplant evaluation were collected and analyzed. Of 421 patients who underwent CF-LVAD implantation, 13 underwent explantation (3.1%). Twelve HeartMate II and one HeartWare LVAD were explanted. All patients had nonischemic cardiomyopathy. Median time from heart failure diagnosis to LVAD implant was 12 months (interquartile range [IQR], 2–44) and the median time supported on LVAD was 22 months (IQR, 11–28). Two patients died within 30 days of explant. Three additional patients died during the follow-up period and all were noted to be nonadherent to medical therapy. After a mean follow-up duration of 5 years, overall survival was 52%. Mean pre-explant ejection fraction was 49%, which decreased at most recent follow-up to 32%. Mean pre-explant left ventricular internal diameter in diastole (LVIDD) was 4.37 cm and increased to 5.52 cm at most recent follow-up. Continuous-flow left ventricular assist device explantation is feasible and safe in select patients.Keywords
This publication has 24 references indexed in Scilit:
- Molecular Changes After Left Ventricular Assist Device Support for Heart FailureCirculation Research, 2013
- Clinical, Molecular, and Genomic Changes in Response to a Left Ventricular Assist DeviceJACC, 2011
- Heart failure reversal by ventricular unloading in patients with chronic cardiomyopathy: criteria for weaning from ventricular assist devicesEuropean Heart Journal, 2010
- Duration of left ventricular assist device support: Effects on abnormal calcium cycling and functional recovery in the failing human heartThe Journal of Heart and Lung Transplantation, 2010
- Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist DeviceNew England Journal of Medicine, 2009
- Use of a Continuous-Flow Device in Patients Awaiting Heart TransplantationNew England Journal of Medicine, 2007
- Determination of Optimal Duration of Mechanical Unloading for Failing Hearts to Achieve Bridge to Recovery in a Rat Heterotopic Heart Transplantation ModelThe Journal of Heart and Lung Transplantation, 2007
- Mixed MessagesCirculation Research, 2005
- Long-term follow-up of thoratec ventricular assist device bridge-to-recovery patients successfully removed from support after recovery of ventricular functionThe Journal of Heart and Lung Transplantation, 2002
- Influence of prolonged ventricular assistance on myocardial histopathology in intact heartThe Annals of Thoracic Surgery, 1996