The Manifestation of Noncycloplegic Refractive State in Pre-School Children is Dependent on Autorefractor Design
Authors:
- R. SuryakumarRSR. Suryakumar
- W. R. BobierWBW. R. Bobier
- 1 August 2003
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 80 (8) , 578-586
Abstract
To investigate the factors that govern the manifestation of hyperopic refractive errors of pre-school children when tested with and without the application of cycloplegics. Forty-three pre-school children (mean age, 3.68 ± 0.59 years) were tested before and during cycloplegia in the following order: retinoscopy with optical fogging; Retinomax K plus; Welch Allyn SureSight (DAV SureSight), and PowerRefractor. In the case of the PowerRefractor, the children viewed a difference of Gaussian target (0.20 cpd) at 3.5 m in addition to viewing the instrument LED sources. Instruments with close working distances (Retinomax) showed the greatest underestimation of hyperopia and the largest variation, followed by the instruments having a greater working distance (PowerRefractor LED view and retinoscopy). The addition of a far target (PowerRefractor difference of Gaussian view) showed the least underestimation, whereas DAV SureSight showed a mean overestimation of the refractive state. When autorefractors are applied to vision screening of pre-school children without the use of cycloplegics, autorefractor designs must be developed that both stabilize and relax the child’s accommodation. Our results suggest that designs should include large working distances and distant fixation targets.Keywords
This publication has 23 references indexed in Scilit:
- Measurement of Refractive Error in Native American Preschoolers: Validity and Reproducibility of AutorefractionOptometry and Vision Science, 2000
- Accuracy and accommodation capability of a handheld autorefractorJournal of Cataract & Refractive Surgery, 2000
- Measurement of the validity of a preschool vision screening program.American Journal of Public Health, 1999
- Slope-based eccentric photorefraction: theoretical analysis of different light source configurations and effects of ocular aberrationsJournal of the Optical Society of America A, 1997
- Measurement of Astigmatism by Automated Infrared PhotoretinoscopyOptometry and Vision Science, 1997
- Preschool vision screening: Rationale, methodology and outcomeSurvey of Ophthalmology, 1996
- Optics of PhotoretinoscopyOptometry and Vision Science, 1985
- Eccentric PhotorefractionOptometry and Vision Science, 1985
- Vision screening and photorefraction — The relation of refractive errors to strabismus and amblyopiaBehavioural Brain Research, 1983
- Infant Refraction and AccommodationInternational Ophthalmology Clinics, 1980