The effects of spherical aberration on multiphoton fluorescence excitation microscopy
- 11 October 2010
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 242 (2) , 157-165
Abstract
Multiphoton fluorescence excitation microscopy is almost invariably conducted with samples whose refractive index differ from that of the objective immersion medium, conditions that cause spherical aberration. Due to the quadratic nature of multiphoton fluorescence excitation, spherical aberration is expected to profoundly affect the depth dependence of fluorescence excitation. In order to determine the effect of refractive index mismatch in multiphoton fluorescence excitation microscopy, we measured signal attenuation, photobleaching rates and resolution degradation with depth in homogeneous samples with minimal light scattering and absorption over a range of refractive indices. These studies demonstrate that signal levels and resolution both rapidly decline with depth into refractive index mismatched samples. Analyses of photobleaching rates indicate that the preponderance of signal attenuation with depth results from decreased rates of fluorescence excitation, even in a system with a descanned emission collection pathway. Similar results were obtained in analyses of fluorescence microspheres embedded in rat kidney tissue, demonstrating that spherical aberration is an important limiting factor in multiphoton fluorescence excitation microscopy of biological samples.Keywords
This publication has 25 references indexed in Scilit:
- Photobleaching2006
- Guiding Principles of Specimen Preservation for Confocal Fluorescence Microscopy2006
- A common aberration with water‐immersion objective lensesJournal of Microscopy, 2004
- Characterizing point spread functions of two-photon fluorescence microscopy in turbid mediumJournal of Biomedical Optics, 2003
- Refractive-index-mismatch induced aberrations in single-photon and two-photon microscopy and the use of aberration correctionJournal of Biomedical Optics, 2001
- Influence of optical properties on two-photon fluorescence imaging in turbid samplesApplied Optics, 2000
- Smart microscope: an adaptive optics learning system for aberration correction in multiphoton confocal microscopyOptics Letters, 2000
- Imaging of optically thick specimen using two-photon excitation microscopyMicroscopy Research and Technique, 1999
- Imaging properties in two-photon excitation microscopy and effects of refractive-index mismatch in thick specimensApplied Optics, 1999
- Multiphoton Excitation Provides Optical Sections from Deeper within Scattering Specimens than Confocal ImagingBiophysical Journal, 1998