Impact of Silicone Hydrogel Lenses and Solutions on Corneal Epithelial Permeability
- 1 June 2013
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 90 (6) , 546-556
Abstract
Purpose: The primary purpose of this pilot study was to compare epithelial barrier function (EBF) and staining in a small group of participants using a silicone hydrogel (SH) lens worn on a daily basis with two different care regimens. Secondarily, the aim was to see if there was any correlation between corneal staining and EBF. Methods: The corneal EBF of 10 non–lens wearers (control) and 15 age‐matched asymptomatic SH contact lens wearers (test) were assessed using fluorophotometry. Biomicroscopy was performed to assess corneal staining after the EBF was measured. The lens wearers wore PureVision (FDA group V) SH lenses for two consecutive 1‐month periods while using either Alcon Opti‐Free Express or Renu Fresh using a randomized, investigator‐masked, crossover design. Control subjects were assessed on one occasion, and lens wearers were examined before fitting with lenses and after 7, 14, and 28 days of lens wear, with each combination. Results: Compared with the control group, both study groups had an increase in epithelial permeability at baseline (p ≤ 0.04). There were no changes in EBF during the treatment period for either solution (p = 0.87). A significant difference in EBF was found between the test groups during the treatment period (p = 0.02), with greater permeability in the Renu Fresh–disinfected lenses. There was poor correlation between corneal staining and EBF ( r = 0.35, p > 0.05) because of large individual variations. Conclusions: Daily wear of highly oxygen‐permeable SH lenses increases corneal epithelial permeability to fluorescein probably because of increased mechanical effects. In addition, certain lens‐solution interactions can add to this effect, as seen in this study. Despite having a low amount of central corneal staining in the Renu Fresh group, staining and EBF did not prove to be well correlated. The presence of central corneal staining is a confounding factor when measuring EBF.Keywords
This publication has 43 references indexed in Scilit:
- Corneal staining and comfort observed with traditional and silicone hydrogel lenses and multipurpose solution combinationsOptometry - Journal of the American Optometric Association, 2008
- Objective and Subjective Responses in Patients Refitted to Daily‐Wear Silicone Hydrogel Contact LensesOptometry and Vision Science, 2006
- The Max Schapero Memorial Award Lecture 2004: Contact Lenses on and in the Cornea, What the Eye NeedsOptometry and Vision Science, 2006
- Silicone Hydrogel Contact Lenses and the Ocular SurfaceThe Ocular Surface, 2006
- Corneal Staining and Subjective Symptoms With Multipurpose Solutions as a Function of TimeEye & Contact Lens: Science & Clinical Practice, 2005
- A Novel Grading Method for Superficial Punctate Keratopathy Magnitude and Its Correlation With Corneal Epithelial PermeabilityArchives of Ophthalmology (1950), 2003
- Asymptomatic Corneal Staining Associated with the Use of Balafilcon Silicone-Hydrogel Contact Lenses Disinfected with a Polyaminopropyl Biguanide-Preserved Care RegimenOptometry and Vision Science, 2002
- Characteristics of the Human Ocular Surface EpitheliumProgress in Retinal and Eye Research, 2001
- Oxygen Permeability of a New Type of High Dk Soft Contact Lens MaterialOptometry and Vision Science, 1998
- Comparison of Fluorescein and Rose Bengal StainingOphthalmology, 1992