High-Resolution Measurements of Leakage Flow Inside the Hinge of a Large-scale Bileaflet Mechanical Heart Valve Hinge Model
- 24 June 2019
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 10 (3) , 469-481
Abstract
Purpose It is believed that non-physiological leakage flow through hinge gaps during diastole contributes to thrombus formation in Bileaflet Mechanical Heart Valves (BMHVs). Because of the small scale and difficulty of experimental access, fluid dynamics inside the hinge cavity has not yet been characterised in detail. The objective is to investigate small-scale structure inside the hinge experimentally, and gain insight into its role in stimulating cellular responses. Methods An optically accessible scaled-up model of a BMHV hinge was designed and built, preserving dynamic similarity to a clinical BMHV. Particle Image Velocimetry (PIV) was used to visualize and quantify the flow fields inside the hinge at physiological Reynolds number and dimensionless pressure drop. The flow was measured at in-plane and out-of-plane spatial resolution of 32 and 86 μm, respectively, and temporal resolution of \(297\,\mu\hbox{s}.\) Results Likely flow separation on the ventricular surface of the cavity has been observed for the first time, and is a source of unsteadiness and perhaps turbulence. The shear stress found in all planes exceeds the threshold of platelet activation, ranging up to 168 Pa. Conclusions The scale-up approach provided new insight into the nature of the hinge flow and enhanced understanding of its complexity. This study revealed flow features that may induce blood element damage.
Keywords
Funding Information
- Science Foundation Ireland (RFP2011)
This publication has 42 references indexed in Scilit:
- Near Valve Flows and Potential Blood Damage During Closure of a Bileaflet Mechanical Heart ValveJournal of Biomechanical Engineering, 2011
- High-Resolution Measurement of the Unsteady Velocity Field to Evaluate Blood Damage Induced by a Mechanical Heart ValveAnnals of Biomedical Engineering, 2011
- Numerical Investigation of the Performance of Three Hinge Designs of Bileaflet Mechanical Heart ValvesAnnals of Biomedical Engineering, 2010
- High-Shear Stress Sensitizes Platelets to Subsequent Low-Shear ConditionsAnnals of Biomedical Engineering, 2010
- Towards Non-thrombogenic Performance of Blood Recirculating DevicesAnnals of Biomedical Engineering, 2010
- Simulation of the Three-Dimensional Hinge Flow Fields of a Bileaflet Mechanical Heart Valve Under Aortic ConditionsAnnals of Biomedical Engineering, 2009
- Models of Flow-Induced Loading on Blood Cells in Laminar and Turbulent Flow, with Application to Cardiovascular Device FlowAnnals of Biomedical Engineering, 2007
- Flow in Prosthetic Heart Valves: State-of-the-Art and Future DirectionsAnnals of Biomedical Engineering, 2005
- Comparison of the Hinge Flow Fields of Two Bileaflet Mechanical Heart Valves under Aortic and Mitral ConditionsAnnals of Biomedical Engineering, 2004
- Hemolysis Near a Transversely Oscillating WireScience, 1970