Intraocular lenses for presbyopia correction
Authors:
- David S. RootmanDRDavid S. Rootman
- 1 January 2012
- journal article
- review article
- Published by Wolters Kluwer Health in Current Opinion in Ophthalmology
- Vol. 23 (1) , 40-46
Abstract
To discuss the development of presbyopia-correcting intraocular lenses (IOLs), what we have learned since their introduction a few decades ago, what are the options currently on the market, and where the technology is heading in the future. Multifocal and accommodating IOLs have gone through several modifications to improve distance, intermediate and near vision compared to their predecessors. These modifications have also targeted unwanted side-effects such as glare and halos in the multifocal lenses and inconsistent near-vision results in the accommodating IOLs and although the results have improved, they are far from perfect. Therefore, careful patient selection for each of these technologies is crucial for success and patient satisfaction. Presbyopia correction remains a great challenge in cataract and refractive surgery. In this article, we review the development of presbyopia-correcting IOLs, starting from the simple, two-zone, multifocal, refractive models introduced 2 decades ago, the current Food and Drug Administration (FDA) approved multifocal and accommodating lenses as well as those undergoing FDA trials and take a look into developing technologies that may be available to us in the future.Keywords
This publication has 72 references indexed in Scilit:
- Combined Correction of Axial Hyperopia and Astigmatism Using the Light Adjustable Intraocular LensOphthalmology, 2011
- Quality of life evaluation after implantation of 2 multifocal intraocular lens models and a monofocal modelJournal of Cataract & Refractive Surgery, 2011
- Effect of +3.00 diopter and +4.00 diopter additions in multifocal intraocular lenses on defocus profiles, patient satisfaction, and contrast sensitivityJournal of Cataract & Refractive Surgery, 2011
- Conductive keratoplasty for the treatment of presbyopia: comparative study between post- and non-LASIK eyesClinical Ophthalmology, 2011
- Long-term reading performance in patients with bilateral dual-optic accommodating intraocular lensesJournal of Cataract & Refractive Surgery, 2010
- Improvements in patient-reported outcomes and visual acuity after bilateral implantation of multifocal intraocular lenses with +3.0 diopter addition: Multicenter clinical trialJournal of Cataract & Refractive Surgery, 2010
- Comparison of reading performance after bilateral implantation of multifocal intraocular lenses with +3.00 or +4.00 diopter additionJournal of Cataract & Refractive Surgery, 2010
- The Quality of Life Associated with PresbyopiaAmerican Journal of Ophthalmology, 2008
- Capsular bag refilling using a new accommodating intraocular lensJournal of Cataract & Refractive Surgery, 2008
- Polymer Refilling of Presbyopic Human Lenses In Vitro Restores the Ability to Undergo Accommodative ChangesInvestigative Ophthalmology & Visual Science, 2003