Survival of Escherichia coli in Airborne and Settled Poultry Litter Particles
Open Access
Abstract
Airborne Escherichia coli (E. coli) in the poultry environment can migrate inside and outside houses through air movement. The airborne E. coli, after settling on surfaces, could be re-aerosolized or picked up by vectors (e.g., caretakers, rodents, transport trucks) for further transmission. To assess the impacts of airborne E. coli transmission among poultry farms, understanding the survivability of the bacteria is necessary. The objective of this study is to determine the survivability of airborne E. coli, settled E. coli, and E. coli in poultry litter under laboratory environmental conditions (22–28 °C with relative humidity of 54–63%). To determine the survivability of airborne E. coli, an AGI-30 bioaerosol sampler (AGI-30) was used to collect the E. coli at 0 and 20 min after the aerosolization. The half-life time of airborne E. coli was then determined by comparing the number of colony-forming units (CFUs) of the two samplings. To determine the survivability of settled E. coli, four sterile Petri dishes were placed on the chamber floor right after the aerosolization to collect settled E. coli. The Petri dishes were then divided into two groups, with each group being quantified for culturable E. coli concentrations and dust particle weight at 24-h intervals. The survivability of settled E. coli was then determined by comparing the number of viable E. coli per milligram settled dust collected in the Petri dishes in the two groups. The survivability of E. coli in the poultry litter sample (for aerosolization) was also determined. Results show that the half-life time of airborne E. coli was 5.7 ± 1.2 min. The survivability of E. coli in poultry litter and settled E. coli were much longer with the half-life time of 15.9 ± 1.3 h and 9.6 ± 1.6 h, respectively. In addition, the size distribution of airborne E. coli attached to dust particles and the size distribution of airborne dust particles were measured by using an Andersen impactor and a dust concentration monitor (DustTrak). Results show that most airborne E. coli (98.89% of total E. coli) were carried by the dust particles with aerodynamic diameter larger than 2.1 µm. The findings of this study may help better understand the fate of E. coli transmitted through the air and settled on surfaces and evaluate the impact of airborne transmission in poultry production.Keywords
Funding Information
- U.S. Department of Agriculture (6064-13000-013-00D)
This publication has 33 references indexed in Scilit:
- Airborne Microorganisms From Livestock Production Systems and Their Relation to DustCritical Reviews in Environmental Science and Technology, 2014
- Bacteria–surface interactionsSoft Matter, 2013
- Effects of Relative Humidity and Spraying Medium on UV Decontamination of Filters Loaded with Viral AerosolsApplied and Environmental Microbiology, 2012
- Extraintestinal Pathogenic Escherichia coli: A Combination of Virulence with Antibiotic ResistanceFrontiers in Microbiology, 2012
- Investigation of the Efficiencies of Bioaerosol Samplers for Collecting Aerosolized Bacteria Using a Fluorescent Tracer. II: Sampling Efficiency and Half-Life TimeAerosol Science and Technology, 2011
- Microwave sterilization of growth medium alleviates inhibition of Aggregatibacter actinomycetemcomitans by Maillard reaction productsJournal of Microbiological Methods, 2009
- Transport Of Fecal Bacteria From Poultry Litter and Cattle Manures Applied to PasturelandWater, Air, & Soil Pollution, 2006
- The survival of Escherichia coli O157 on a range of metal surfacesInternational Journal of Food Microbiology, 2005
- Increased Airborne Bacterial Survival as a Function of Particle Content and SizeAerosol Science and Technology, 1997
- Dust in livestock buildings—Review of some aspectsJournal of Agricultural Engineering Research, 1986