Tracheal sounds accurately detect apnea in patients recovering from anesthesia
Authors:
- 11 August 2018
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 33 (3) , 437-444
Abstract
Apnea should be monitored continuously in the post anesthesia care unit (PACU) to avoid serious complications. It has been confirmed that tracheal sounds can be used to detect apnea during sedation in healthy subjects, but the performance of this acoustic method has not been evaluated in patients with frequent apnea events in the PACU. Tracheal sounds were acquired from the patients in the PACU using a microphone encased in a plastic bell. Concurrently, a processed nasal pressure signal was used as a reference standard to identify real respiratory events. The logarithm of the tracheal sound variance (log-var) was used to detect apnea, and the results were compared to the reference method. Sensitivity, specificity, positive likelihood ratios (PLR), and negative likelihood ratios (NLR) were calculated. One hundred and twenty-one patients aged 55.5 ± 13.2 years (mean ± SD) with a body mass index of 24.6 ± 3.7 kg/m2 were included in data analysis. The total monitoring time was 52.6 h. Thirty-four patients experienced 236 events of apnea lasting for a total of 122.2 min. The log-var apnea detection algorithm detected apnea with 92% sensitivity, 98% specificity, 46 PLR and 0.08 NLR. The performance of apnea detection in the PACU using the log-var tracheal sounds method proved to be reliable and accurate. Tracheal sounds could be used to minimize the potential risks from apnea in PACU patients.Keywords
Funding Information
- National Natural Science Foundation of China (81401485)
This publication has 30 references indexed in Scilit:
- A risk stratification algorithm using non-invasive respiratory volume monitoring to improve safety when using post-operative opioids in the PACUJournal of Clinical Monitoring and Computing, 2016
- Capnography enhances surveillance of respiratory events during procedural sedation: a meta-analysisJournal of Clinical Anesthesia, 2011
- The effect of intravenous opioid patient-controlled analgesia with and without background infusion on respiratory depression: A meta-analysisJournal of Opioid Management, 2010
- Incidence, Reversal, and Prevention of Opioid-induced Respiratory DepressionAnesthesiology, 2010
- Accuracy of Postoperative End-tidal Pco2Measurements with Mainstream and Sidestream Capnography in Non-obese Patients and in Obese Patients with and without Obstructive Sleep ApneaAnesthesiology, 2009
- Continuous Oximetry/Capnometry Monitoring Reveals Frequent Desaturation and Bradypnea During Patient-Controlled AnalgesiaAnesthesia & Analgesia, 2007
- Why don't nurses monitor the respiratory rates of patients?British Journal of Nursing, 2006
- Clinical experience with patient-controlled analgesia using continuous respiratory monitoring and a smart infusion systemAmerican Journal of Health-System Pharmacy, 2006
- The vexatious vital: Neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triageAnnals of Emergency Medicine, 2005
- Supplemental Oxygen Impairs Detection of Hypoventilation by Pulse OximetryChest, 2004