Abstract
To analyze the surface optics of 4 currently available intraocular lenses (IOLs) with atomic force microscopy. Licryl Laboratory, University of Calabria, Rende, Italy. The surface roughness and topography of poly(methyl methacrylate) (PMMA), silicone, hydrophobic, and hydrophilic acrylic IOLs were evaluated with atomic force microscopy in contact mode. The analysis was performed in a liquid environment using cantilevers with a 0.01 Newtonw/meter nominal elastic constant. Measurements were made over areas of 10 microm2 on different locations of the posterior optic surface of the IOL. Atomic force microscopy permitted high-resolution imaging of IOL optic surface characteristics. Surface topography showed different features with respect to the lens biomaterial. The root-mean-square roughness of the IOL optic surface was significantly different between lenses of various materials (P < .001). The hydrophobic acrylic and silicone IOLs had the lowest mean surface roughness, 3.8 nm +/- 0.2 (SD) and 4.0 +/- 0.5 nm, respectively, and the 2 PMMA IOLs had the highest mean surface roughness, 6.6 +/- 0.3 nm and 7.0 +/- 0.6 nm. Atomic force microscopy was effective and accurate in analyzing IOL optics. The surface topography of IOLs may vary with different manufacturing processes.Keywords
This publication has 35 references indexed in Scilit:
- Neodymium:YAG laser posterior capsulotomy after implantation of AcrySof intraocular lensesJournal of Cataract & Refractive Surgery, 2004
- Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2002
- Biocompatibility of hydrophilic intraocular lensesJournal of Cataract & Refractive Surgery, 2002
- Uveal and capsular biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lensesJournal of Cataract & Refractive Surgery, 2002
- Evaluation of cellular adhesions on silicone and poly(methyl methacrylate) intraocular lenses in monkey eyesJournal of Cataract & Refractive Surgery, 2001
- Cellular reaction on the anterior surface of 4 types of intraocular lensesJournal of Cataract & Refractive Surgery, 2001
- Shape of lens epithelial cells after intraocular lens implantationJournal of Cataract & Refractive Surgery, 2001
- Eradication of posterior capsule opacificationOphthalmology, 2001
- Lens epithelial cell regression on the posterior capsule with different intraocular lens materialsBritish Journal of Ophthalmology, 1998
- Comparison of the postoperative inflammatory response in the normal eye with heparin-surface-modified and poly(methyl methacrylate) intraocular lensesJournal of Cataract & Refractive Surgery, 1995