Percutaneous Versus Transcutaneous Bone Conduction Implant System
Authors:
- Bo HåkanssonBHBo Håkansson
- Måns Eeg-OlofssonMEMåns Eeg-Olofsson
- Sabine ReinfeldtSRSabine Reinfeldt
- Stefan StenfeltSSStefan Stenfelt
- Gösta GranströmGGGösta Granström
- 1 December 2008
- journal article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 29 (8) , 1132-1139
Abstract
Percutaneous bone-anchored hearing aid (BAHA) is an important rehabilitation alternative for patients who have conductive or mixed hearing loss. However, these devices use a percutaneous and bone-anchored implant that has some drawbacks reported. A transcutaneous bone conduction implant system (BCI) is proposed as an alternative to the percutaneous system because it leaves the skin intact. The BCI transmits the signal to a permanently implanted transducer with an induction loop system through the intact skin. The aim of this study was to compare the electroacoustic performance of the BAHA Classic-300 with a full-scale BCI on a cadaver head in a sound field. The BCI comprised the audio processor of the vibrant sound bridge connected to a balanced vibration transducer (balanced electromagnetic separation transducer). Implants with snap abutments were placed in the parietal bone (Classic-300) and 15-mm deep in the temporal bone (BCI). The vibration responses at the ipsilateral and contralateral cochlear promontories were measured with a laser Doppler vibrometer, with the beam aimed through the ear canal. Results show that the BCI produces approximately 5 dB higher maximum output level and has a slightly lower distortion than the Classic-300 at the ipsilateral promontorium at speech frequencies. At the contralateral promontorium, the maximum output level was considerably lower for the BCI than for the Classic-300 except in the 1-2 kHz range, where it was similar. Present results support the proposal that a BCI system can be a realistic alternative to a BAHA.Keywords
This publication has 11 references indexed in Scilit:
- Unilateral Deafness After Acoustic Neuroma SurgeryOtology & Neurotology, 2006
- Revision BAHA SurgeryOtolaryngologic Clinics of North America, 2006
- Latent Demand for the Bone-Anchored Hearing AidOtology & Neurotology, 2006
- How we do it: Frequency of skin necrosis after BAHA surgeryClinical Otolaryngology, 2006
- Perioperative Complications with the Bone‐Anchored Hearing AidOtolaryngology–Head and Neck Surgery, 2006
- Consensus Statements on the BAHA System: Where Do We Stand at Present?Annals of Otology, Rhinology & Laryngology, 2005
- Bone-anchored hearing aidsOtolaryngologic Clinics of North America, 2001
- Evaluation of implant losses and skin reactions around extraoral bone‐anchored implants: A 0‐ to 8‐year follow‐upOtolaryngology–Head and Neck Surgery, 2000
- Vibration characteristics of bone conducted sound in vitroThe Journal of the Acoustical Society of America, 2000
- Skull Simulator for Direct Bone Conduction Hearing DevicesScandinavian Audiology, 1989