High Performance Liquid Chromatographic Analysis of Rifampin and Related Impurities in Pharmaceutical Formulations
Authors:
- 1 January 1979
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 2 (3) , 365-371
Abstract
High pressure liquid chromatography was employed for the assay of rifampin in capsules. A reverse phase RP-2 column and a mobile phase of 48% methanol, 5% tetrahydrofuran and 47% 0.05 M ammonium formate (pH 7.3) were used with detection at 254 nm. Rifampin was separated from all its major degradation products and quantitated.Keywords
This publication has 3 references indexed in Scilit:
- Analysis of rifampicin and of its hydrogenated deriavites by high-performance liquid chromatographyJournal of Chromatography A, 1978
- Quantitative assay of rifampicin and three of its metabolites in human plasma, urine and saliva by high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1978
- Rifampicin: A New Orally Active RifamycinChemotherapy, 1966