A Randomized, Controlled Comparison of Cardiopulmonary Resuscitation Performed on the Floor andon a Moving Ambulance Stretcher
Authors:
- Douglas VogelDVDouglas Vogel
- Guy GuimondGGGuy Guimond
- David HostlerDHDavid Hostler
- Henry E. WangHWHenry E. Wang
- James J. MenegazziJMJames J. Menegazzi
- 1 January 2006
- journal article
- research article
- Published by Taylor & Francis in Prehospital Emergency Care
- Vol. 10 (1) , 68-70
Abstract
Recent studies have demonstrated that cardiopulmonary resuscitation (CPR) of poor quality is associated with worsened outcomes. To compare the quality of CPR delivered on the floor with the quality of CPR delivered on a moving stretcher. The authors hypothesized that CPR performed on the floor would be superior to that performed on a moving stretcher. A randomized, crossover experimental design was used. Subjects included emergency medical technician students, paramedic students, and emergency medicine residents. Two-member teams were randomly assigned to perform two-rescuer CPR on a manikin either on the floor or on a moving stretcher. After a 5-minute rest, the teams performed CPR under the opposite condition. Compression and ventilation data were collected using a recording resuscitation manikin. Dependent variables were compression depth, compression rate per minute, percentage of correct chest compressions, tidal volume, and percentage of correct ventilations. Data were compared using two-tailed paired t-test. Sixty-two subjects completed the study. The mean compression depth performed on the floor (39 +/- 9 mm) was greater than that on a moving stretcher (28 +/- 9 mm) (p < 0.001). The mean rates of chest compressions on the floor (110 +/- 17 beats/min) and on a moving stretcher (113 +/- 21 beats/min) were not different (p = 0.49). The percentage of correct compressions performed on the floor (54% +/- 40%) exceeded that on a moving stretcher (21% +/- 29%)(p < 0.001). The percentage of correct ventilations performed on the floor (43% +/- 26%) was greater than that on a moving stretcher (24% +/- 21%)(p < 0.04). Chest compression and ventilation quality of CPR performed on the floor was superior to that of CPR performed on a moving stretcher in this manikin model. The quality of CPR while moving was significantly compromised.Keywords
This publication has 8 references indexed in Scilit:
- Modified cardiopulmonary resuscitation (CPR) instruction protocols for emergency medical dispatchers: rationale and recommendationsResuscitation, 2005
- Quality of Cardiopulmonary Resuscitation During In-Hospital Cardiac ArrestJAMA, 2005
- Quality of Cardiopulmonary Resuscitation During Out-of-Hospital Cardiac ArrestJAMA, 2005
- THE EFFECT OF A VOICE ASSIST MANIKIN (VAM) SYSTEM ON CPR QUALITY AMONG PREHOSPITAL PROVIDERSPrehospital Emergency Care, 2005
- An automated voice advisory manikin system for training in basic life support without an instructor. A novel approach to CPR trainingResuscitation, 2001
- Can Correct Closed-Chest Compressions Be Performed During Prehospital Transport?Prehospital and Disaster Medicine, 1995
- Predicting the Outcome of Unsuccessful Prehospital Advanced Cardiac Life SupportJAMA, 1993
- Distinct Criteria for Termination of Resuscitation in the Out-of-Hospital SettingJAMA, 1993