Advancing 2D fluorescence online monitoring in microtiter plates by separating scattered light and fluorescence measurement, using a tunable emission monochromator
Open Access
- 23 June 2023
- journal article
- research article
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 120 (10) , 2925-2939
Abstract
Online fluorescence monitoring has become a key technology in modern bioprocess development, as it provides in‐depth process knowledge at comparably low costs. In particular, the technology is widely established for high‐throughput microbioreactor cultivation systems, due to its noninvasive character. For microtiter plates, previously also multi‐wavelength 2D fluorescence monitoring was developed. To overcome an observed limitation of fluorescence sensitivity, this study presents a modified spectroscopic setup, including a tunable emission monochromator. The new optical component enables the separation of the scattered and fluorescent light measurements, which allows for the adjustment of integration times of the charge‐coupled device detector. The resulting increased fluorescence sensitivity positively affected the performance of principal component analysis for spectral data of Escherichia coli batch cultivation experiments with varying sorbitol concentration supplementation. In direct comparison with spectral data recorded at short integration times, more biologically consistent signal dynamics were calculated. Furthermore, during partial least square regression for E. coli cultivation experiments with varying glucose concentrations, improved modeling performance was observed. Especially, for the growth‐uncoupled acetate concentration, a considerable improvement of the root‐mean‐square error from 0.25 to 0.17 g/L was achieved. In conclusion, the modified setup represents another important step in advancing 2D fluorescence monitoring in microtiter plates.Keywords
Funding Information
- Innovative Medicines Initiative (777397)
This publication has 47 references indexed in Scilit:
- Improving accuracy of cell and chromophore concentration measurements using optical densityBMC Biophysics, 2013
- Development of a modified Respiration Activity Monitoring System for accurate and highly resolved measurement of respiration activity in shake flask fermentationsJournal of Biological Engineering, 2012
- In-situmicroscopy and 2D fluorescence spectroscopy as online methods for monitoring CHO cells during cultivationBMC Proceedings, 2011
- Chemometrics applications in biotech processes: A reviewBiotechnology Progress, 2011
- Validation of a high-throughput fermentation system based on online monitoring of biomass and fluorescence in continuously shaken microtiter platesMicrobial Cell Factories, 2009
- Robo-Lector – a novel platform for automated high-throughput cultivations in microtiter plates with high information contentMicrobial Cell Factories, 2009
- A Study of Long-Term Effects on Plasmid-Containing Escherichia coli in Carbon-Limited Chemostat Using 2D-Fluorescence SpectrofluorimetryBiotechnology Progress, 2006
- The crystal structure of Bacillus subtili lipase: a minimal α/β hydrolase fold enzymeJournal of Molecular Biology, 2001
- Fluorescence Quantum Yield Measurements: Vitamin B 6 CompoundsScience, 1965
- ber den Astigmatismus bei SpiegelspektrometernThe European Physical Journal A, 1930