How should low-contrast detail detectability be measured in fluoroscopy?
Authors:
- Markku J. TapiovaaraMTMarkku J. Tapiovaara
- Michael SandborgMSMichael Sandborg
- 26 August 2004
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 31 (9) , 2564-2576
Abstract
The relationship and precision of four methods for measuring the low-contrast detail detectability in fluoroscopic imaging were studied. These included the physical measurement of the accumulation rate of the square of the signal-to-noise ratio (SNR(rate)2), two-alternative forced-choice (2-AFC) experiments, sixteen-alternative forced-choice (16-AFC) experiments and subjective determination of the threshold contrast. The precision and sensitivity of the threshold contrast measurement were seen to be modest in the constancy testing of fluoroscopic equipment: only large changes in system performance could be reliably detected by that method. The measurement of the SNR(rate)2 is suggested instead. The relationship between the results of the various methods were studied, and it was found that human performance can be related to SNR(rate)2 by introducing the concept of the effective image information integration time (t(eff)). When measured for an unlimited observation time, it depicts the saturation of human performance in detecting a static low-contrast detail in dynamic image noise. Here, t(eff) was found to be about 0.6 s in 2-AFC tests and 0.3 s in 16-AFC tests.Keywords
This publication has 23 references indexed in Scilit:
- Efficiency of low‐contrast detail detectability in fluoroscopic imagingMedical Physics, 1997
- Update on the recommended viewing protocol for FAXIL threshold contrast detail detectability test objects used in television fluoroscopyBritish Journal of Radiology, 1995
- SNR and noise measurements for medical imaging. II. Application to fluoroscopic X-ray equipmentPhysics in Medicine & Biology, 1993
- Physical aspects of photostimulable phosphor computed radiographyBritish Journal of Radiology, 1993
- SNR and noise measurements for medical imaging: I. A practical approach based on statistical decision theoryPhysics in Medicine & Biology, 1993
- Analysis of variations in contrast-detail measurements performed on image intensifier-television systemsPhysics in Medicine & Biology, 1992
- Image quality index (IQI) for screen-film mammographyPhysics in Medicine & Biology, 1991
- A clinical evaluation of contrast–detail analysis for ultrasound imagesMedical Physics, 1990
- A Set of X-Ray Test Objects for Quality Control in Television FluoroscopyBritish Journal of Radiology, 1985
- The Sensitivity Performance of the Human Eye on an Absolute Scale*Journal of the Optical Society of America, 1948