The Learning Curve Associated With Thoracoscopic Spinal Instrumentation
Authors:
- Baron S. LonnerBLBaron S. Lonner
- Carrie ScharfCSCarrie Scharf
- Darryl AntonacciDADarryl Antonacci
- Yael GoldsteinYGYael Goldstein
- Georgia PanagopoulosGPGeorgia Panagopoulos
- 1 December 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 30 (24) , 2835-2840
Abstract
Consecutive case prospective radiographic and medical record review. To define the learning curve associated with thoracoscopic spinal instrumentation by evaluating operative data and early outcomes of 1 surgeon’s (B.L.) cases. Thoracoscopic spinal instrumentation for the treatment of thoracic adolescent idiopathic scoliosis has emerged as an alternative to open anterior and posterior techniques. The technique is technically demanding and has been perceived as having a prohibitive learning curve. The operative reports, charts, and surgeon’s database were used to evaluate operating time, estimated blood loss, levels fused, complication rate, blood transfusions, and curve correction, among other variables. For purposes of analysis, the entire cohort was divided into 2 groups of 28 and 29 patients, respectively, and then 4 groups of 14 patients (the last group with 15) were used for comparison. The records of 57 patients were evaluated. No significant difference in estimated blood loss or number of levels fused was noted for either comparison (P = 0.46 and P = 0.66, respectively). There was no significant difference in blood transfusion requirements, with 7% in group 1 and 18% in group 2 (P = 0.35). Operating time was significantly less after 28 patients were operated on 6.2 ± 1.3 hours versus 5.3 ± 1.2 hours (P = 0.011). Percent curve correction was significantly better after 28 cases were performed, 54.4 ± 17.9 in the former groups versus 65.7 ± 10.4 in the latter half of cases (P = 0.005). Complications were evenly distributed throughout the series. No significant differences were observed between the 2 groups in terms of rate of complication (P = 0.50). No major complications, such as neurologic deficit or significant hemorrhage, were observed. The learning curve associated with thoracoscopic spinal instrumentation appears to be acceptable. Significant differences were noted in operating time and percent curve correction after 28 cases. The complication rates remained stable throughout the surgeon’s experience.Keywords
This publication has 12 references indexed in Scilit:
- Thoracoscopic transdiaphragmatic approach to thoracolumbar junction fracturesThe Spine Journal, 2004
- Use of Video-Assisted Thoracoscopic Surgery to Reduce Perioperative Morbidity in Scoliosis SurgerySpine, 2003
- Thoracoscopic Anterior Instrumentation and Fusion for Idiopathic ScoliosisJournal of the American Academy of Orthopaedic Surgeons, 2003
- Evaluation of Ventilatory Efficiency During Exercise in Patients With Idiopathic Scoliosis Undergoing Spinal FusionSpine, 2002
- Endoscopic instrumentation, correction, and fusion of idiopathic scoliosisThe Spine Journal, 2001
- Prospective Pulmonary Function Evaluation Following Open Thoracotomy for Anterior Spinal Fusion in Adolescent Idiopathic ScoliosisSpine, 2000
- Defining the Pediatric Spinal Thoracoscopy Learning CurveSpine, 2000
- A Prospective Evaluation of Pulmonary Function in Patients With Adolescent Idiopathic Scoliosis Relative to the Surgical Approach Used for Spinal ArthrodesisSpine, 2000
- Anterior Release and Fusion in Pediatric Spinal DeformitySpine, 1997
- Postoperative pain-related morbidity: Video-assisted thoracic surgery versus thoracotomyThe Annals of Thoracic Surgery, 1993