Circumferential wires as a supplement to intramedullary nailing in unstable trochanteric hip fractures
Authors:
- Ilija BanIBIlija Ban
- Lasse BirkelundLBLasse Birkelund
- Henrik PalmHPHenrik Palm
- Michael BrixMBMichael Brix
- Anders TroelsenATAnders Troelsen
Open Access
- 13 February 2012
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 83 (3) , 240-243
Abstract
Fixation of unstable trochanteric fractures is challenging. Application of a circumferential wire may facilitate bone contact and avoid postoperative fracture displacement. However, the use of circumferential wires remains controversial due to possible disturbance of the blood supply to the underlying bone. We evaluated the results of applied circumferential wires, concentrating mainly on complications and reoperations. 60 patients with unstable trochanteric fractures and use of circumferential wires (1 or more) and an intramedullary nail were included from 2 centers. We retrospectively assessed complications and reoperation rates within the first postoperative year. In 37 of the 60 patients, 2 or more circumferential wires were used. Anatomic reduction was achieved in 24 of the patients and a total cortical displacement of ≤ 10 mm was achieved in 26 other patients. 6 of the 43 patients with radiographic audit after 12 weeks sustained a subsequent fracture displacement of more than 5 mm. 4 patients underwent reoperation: 1 due to deep infection, 1 due to technical failure during osteosynthesis, 1 had a screw cut out, and 1 sustained a new fracture following a new fall. Application of circumferential wires as a supplement to intramedullary nails in unstable trochanteric fractures is an option as it provides good primary reduction which, in most patients, is maintained over time-with no apparent increase in reoperation rate. Based on our results and on other reports, the use of circumferential wires does not appear to be harmful as sometimes claimed.Keywords
This publication has 12 references indexed in Scilit:
- A new algorithm for hip fracture surgeryActa Orthopaedica, 2011
- Subtrochanteric hip fractures treated with cerclage cables and long cephalomedullary nails: A review of 17 consecutive cases over 2 yearsInjury, 2011
- Clamp-Assisted Reduction of High Subtrochanteric Fractures of the FemurJournal of Bone and Joint Surgery, 2009
- Prediction of fixation failure after sliding hip screw fixationInjury, 2004
- Unstable trochanteric femoral fractures: extramedullary or intramedullary fixationInjury, 2004
- Effect of circumferential bands on cortical vascularity and viabilityJournal of Orthopaedic Research, 1991
- Cerclage wiring in the management of comminuted fractures of the femoral shaftInjury, 1987
- Microvascular and histologic effect of circumferential wire on appositional bone growth in immature dogsJournal of Orthopaedic Research, 1985
- The treatment of fractions of the shaft of the femur using nylon cerclage.1982
- Fracture Nonunion Resulting from Cerclage AppliancesJournal of the American Veterinary Medical Association, 1974