The effect of thermal conditions on CO2 distribution in a greenhouse

Authors:

Abstract
An experiment was conducted to determine the extent to which the distribution of CO 2 depended on the thermal conditions within a greenhouse. The CO 2 levels and the change in the horizontal temperature gradient were measured throughout the greenhouse. The appropriate level of CO 2 and the concentrated mass of CO 2 were analyzed at predetermined points to verify the relation between CO 2 and temperature to establish whether a constant distribution existed throughout the facility. As a result, when using the membrane system, the CO 2 concentrations external and internal to the greenhouse were measured to be 380~440 ppm and 1020 ppm, respectively. The efficiency of the membrane system was shown to be about 268%. The highest CO 2 concentration was about 1000 ppm near the floor, where the temperature was the lowest. In contrast, at a height of 2.50 m, where the temperature was the highest, the CO 2 concentration was the lowest at about 400~500 ppm.