Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials
Open Access
- 12 May 2021
- journal article
- review article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 22 (1) , 1-14
Abstract
Background: The outcomes for volar locking plate (VLP) and external fixation (EF) in distal radius fracture cases remain controversial. The current study of randomized controlled trials (RCTs) aimed to assess VLP and EF, which might benefit distal radius fracture cases. Methods: RCTs comparing VLP and EF in distal radius fracture cases, until 18 March 2020, were systematically reviewed and summarized. The functional and radiographic outcomes, together with complications, for distal radius fracture cases, were evaluated. Results: In total, 12 studies comprising 1205 distal radius fracture cases were included. The VLP group had observed lower disability in the arm shoulder and hand score (DASH) at 3rd, 6th, and 12th -month post-operation, with the mean differences (MDs) of − 10.43 (95 % CI = − 15.77 to − 5.08, P < 0.01), − 3.48 (95 % CI = − 6.37 to − 0.59, P = 0.02), and − 4.13 (95 % CI = − 6.94 to − 1.33, P < 0.01), respectively. The VLP group also had lower visual analog scale scores (VAS) compared to the EF group, with MDs of − 0.10 (95 % CI = − 0.18 to − 0.03, P < 0.01) for the former at 6th -month post-operation. Also, the EF group exhibited better grip strength than that in the VLP group, with MD of 12.48 (95 % CI = 7.00–17.95, P < 0.01) at the 3rd month and 4.54 (95 % CI = 0.31–8.76, P = 0.04) at 6th month. No significant differences in radiographic outcomes were observed between the VLP and EF groups (P > 0.05). The VLP group had a lower complication rate than that in the EF group. Conclusions: VLP had a lower DASH score and VAS score but with lower grip strength. No significant differences in radiographic outcomes were observed. VLP had a lower complication rate than that of EF.Keywords
This publication has 38 references indexed in Scilit:
- Functional outcome in patients with unstable distal radius fractures, volar locking plate versus external fixation: a meta-analysisStrategies in Trauma and Limb Reconstruction, 2013
- The Cochrane Collaboration's tool for assessing risk of bias in randomised trialsBMJ, 2011
- External or internal fixation in the treatment of non-reducible distal radial fractures?Acta Orthopaedica, 2011
- A Systematic Review of Outcomes and Complications of Treating Unstable Distal Radius Fractures in the ElderlyThe Journal of Hand Surgery, 2011
- Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 yearActa Orthopaedica, 2010
- Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fracturesActa Orthopaedica, 2009
- A Biomechanic Comparison of an Internal Radiocarpal-Spanning 2.4-mm Locking Plate and External Fixation in a Model of Distal Radius FracturesThe Journal of Hand Surgery, 2006
- Measuring inconsistency in meta-analysesBMJ, 2003
- Recurrent dorsal angulation of the distal radius fracture during dynamic external fixationThe Journal of Hand Surgery, 1998
- Assessing the quality of reports of randomized clinical trials: Is blinding necessary?Controlled Clinical Trials, 1996