A new movement artifact detector for photoplethysmographic signals
Authors:
- 1 July 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2013 (1094687X) , 2295-2299
Abstract
Oximeters are commonly used in abbreviated cardiorespiratory studies (ACS) to monitor blood oxygen saturation and heart rate using the photoplethysmography (PPG) signal. These data are prone to movement artifacts, especially in infants who move or need to be handled often. Therefore segments of PPG data contaminated by movement artifact must be detected as a first stage of analysis. In ACS this identification is generally done manually, by having an expert visually assess the quality of the signal. This is subjective and very time consuming, especially for long data records. For this reason we present a novel detector of PPG movement artifacts that uses moving average filters to remove trends, reduce the effect of white noise, and notch filter pulse-related information. The normalized root mean square of the filtered signal is then used as a detection statistic. We demonstrate its detection properties using a data set from infants recovering from anesthesia, and show that it performs better than other automated methods based on entropy or higher-order statistics. Furthermore, the new method is more robust than the other methods in the presence of large noise.Keywords
This publication has 18 references indexed in Scilit:
- Prediction of extubation readiness in extreme preterm infants based on measures of cardiorespiratory variability2012
- Automated unsupervised respiratory event analysis2011
- Automated Off-Line Respiratory Event Detection for the Study of Postoperative Apnea in InfantsIEEE Transactions on Biomedical Engineering, 2011
- PINK NOISE, 1/fαNOISE, AND THEIR EFFECT ON SOLUTIONS OF DIFFERENTIAL EQUATIONSInternational Journal for Uncertainty Quantification, 2011
- Use of Fourier Series Analysis for Motion Artifact Reduction and Data Compression of Photoplethysmographic SignalsIEEE Transactions on Instrumentation and Measurement, 2008
- Adaptive filtering and alternative calculations revolutionizes pulse oximetry sensitivity and specificity during motion and low perfusion2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2007
- Motion Artifact Reduction in Photoplethysmography Using Independent Component AnalysisIEEE Transactions on Biomedical Engineering, 2006
- Age Terminology During the Perinatal PeriodPediatrics, 2004
- Electromagnetic interference in medical devices: Health Canada's past and current perspectives and activities2002
- Effects of motion, ambient light, and hypoperfusion on pulse oximeter functionJournal of Clinical Anesthesia, 1997