Comparing the Nidek MP‐1 and Humphrey Field Analyzer in Normal Subjects
- 1 November 2011
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 88 (11) , 1288-1297
Abstract
Purpose.: To compare visual fields on the Nidek MP‐1 to those obtained on the Humphrey field analyzer (HFA) in healthy volunteers and assess the effects of differences in stimulus parameters and testing strategies that may influence the interpretation of results in patients. A secondary aim was to establish MP‐1 normative data to calculate the total deviation analyses and global indices analogous to those used by the HFA. Methods.: Fifty healthy volunteers (age 43.5 ± 13.9 years, range, 18 to 68 years) underwent repeat MP‐1 and HFA visual field testing, using the 10‐2 pattern. MP‐1 data were converted to HFA equivalent dB units. Between instrument comparisons of HFA and MP‐1 sensitivities, regression of sensitivity with age and examination duration were assessed. Test‐retest variability was examined between visits. Results.: MP‐1 (mean = 32.82 dB, SD = 1.92 dB) and HFA sensitivities (mean = 32.84 dB, SD = 1.83 dB) were not significantly different (p = 0.759). SD values for the HFA (range, 1.11 to 3.30 dB) were similar to the MP‐1 (range, 0.14 to 2.75 dB). However, asymmetry comparisons between instruments showed significantly decreased superior rather than inferior retinal values for the MP‐1. There was a small but significant difference (p = 0.004) in mean test duration between the MP‐1 (mean = 6:11 min, SD = 1:49 min) and the HFA (mean = 5:14 min, SD = 0:42 min). There was also a difference in the decline of mean sensitivity with age, a decline of 0.1 and 0.4 dB per decade was noted in MP‐1 and HFA sensitivity, respectively. Test‐retest variability was similar between instruments. A small but non‐significant increase in mean sensitivity at the second visit for both the MP‐1 (p = 0.060) and HFA (p = 0.570) was found. Conclusions.: Both instruments showed similar variability and test‐retest variability when results were compared using equivalent units. However, there are important differences in sensitivity values, stimulus parameters, and testing strategies that have to be taken into account when comparisons are made.Keywords
This publication has 31 references indexed in Scilit:
- A comparison between microperimetry and standard achromatic perimetry of the central visual field in eyes with glaucomatous paracentral visual-field defectsBritish Journal of Ophthalmology, 2009
- FIXATION STABILITY MEASUREMENT USING THE MP1 MICROPERIMETERRetina, 2009
- Reading Performance Is Reduced by Parafoveal Scotomas in Patients with Macular Telangiectasia Type 2Investigative Ophthalmology & Visual Science, 2009
- Use of fundus perimetry (microperimetry) to quantify macular sensitivityProgress in Retinal and Eye Research, 2008
- Age‐dependent normative values for differential luminance sensitivity in automated static perimetry using the Octopus 101Acta Ophthalmologica, 2008
- Variability of visual field measurements is correlated with the gradient of visual sensitivityVision Research, 2007
- Fundus Perimetry with the Micro Perimeter 1 in Normal IndividualsComparison with Conventional Threshold PerimetryOphthalmology, 2005
- Gesichtsfeld-Kompendium - Interpretation perimetrischer Befunde Fachübergreifende diagnostische MaßnahmenKlinische Monatsblätter für Augenheilkunde, 1995
- Angioscotomata and morphological features of related vessels in automated perimetry.British Journal of Ophthalmology, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986