Favorable Tissue Effects of Quantum Molecular Resonance Device (Vesalius®) Compared with Standard Electrocautery
Authors:
- M. SchiavonMSM. Schiavon
- F. CalabreseFCF. Calabrese
- S. NicotraSNS. Nicotra
- G. MarulliGMG. Marulli
- G. PozzatoGPG. Pozzato
- C. GiacomettiC. Giacometti
- M. ValenteMVM. Valente
- F. ReaFRF. Rea
- 13 April 2007
- journal article
- research article
- Published by S. Karger AG in European Surgical Research
- Vol. 39 (4) , 222-228
Abstract
Background: Electrosurgical devices are largely employed in thoracic surgery but their use is burdened by extensive necrosis and second intention healing. Methods: A rat model of thoracotomy was performed on 46 adult male rats using a standard electrocautery or a new quantum molecular resonance (QMR) instrument called Vesalius®. Skin, muscle and lung specimens were obtained immediately and 2 weeks after surgery to evaluate acute and late effects. Results: Both in the short- and long-term study, Vesalius produced less severe tissue damage than that of standard electrocautery. Conclusions: The use of the QMR device may provide an alternative to gold-standard electrosurgical devices in thoracic surgery.Keywords
This publication has 13 references indexed in Scilit:
- Use of an electrothermal bipolar tissue sealing system in lung surgeryEuropean Journal of Cardio-Thoracic Surgery, 2006
- Improvement of ‘dynamic analgesia’ does not decrease atelectasis after thoracotomyBritish Journal of Anaesthesia, 2001
- A Comparison of Monopolar Electrosurgery to a New Multipolar Electrosurgical System in a Rat ModelThe Laryngoscope, 2001
- Comparison of the ultrasonic scalpel to CO2 laser and electrosurgery in terms of tissue injury and adhesion formation in a rabbit modelFertility and Sterility, 1997
- Cardiovascular and respiratory effects of tiletamine-zolazepamPharmacology Biochemistry and Behavior, 1993
- Pain after thoracic surgeryActa Anaesthesiologica Scandinavica, 1992
- Xylazine – a review of its pharmacology and use in veterinary medicineJournal of Veterinary Pharmacology and Therapeutics, 1988
- Wound Healing of Skin Incisions Produced by Ultrasonically Vibrating Knife, Scalpel, Electrosurgery, and Carbon Dioxide LaserThe Journal of Dermatologic Surgery and Oncology, 1988
- Histologic evaluation of gingival response to an electrosurgical bladeJournal of Oral and Maxillofacial Surgery, 1987
- Pulmonary procedures assisted by optosurgical and electrosurgical devices: Comparison of damage potentialLasers in Surgery and Medicine, 1987