Broadband reconfigurable instantaneous microwave multifrequency measurement system based on a nonuniform optical frequency comb
Authors:
- 30 September 2024
- journal article
- research article
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (28) , 7556-7565
Abstract
A broadband reconfigurable instantaneous microwave multifrequency measurement system based on a nonuniform optical frequency comb has been proposed and investigated. An amplitude nonuniform optical frequency comb (OFC) with 2l+1 lines is generated using periodic sawtooth wave modulation. One path of the OFC is passed through an optical frequency selector (OFS) to output one of the lines as the optical carrier, which, along with the unknown signal, are input into a dual-parallel Mach–Zehnder modulator (DPMZM) for carrier-suppressed single-sideband (CS-SSB) modulation and then channelized by using demultiplexer (DEMUX1). The other path is input into DEMUX2 for comb line separation. A 90° optical hybrid coupler (OHC) is used to merge the signals output from the two demultiplexers, and a pair of balanced photodetectors (BPD) is employed to convert the optical signals into electrical signals. Finally, the frequency of the unknown microwave signal can be determined by detecting the channel position i in which the signal falls, and the frequency fPD detected within channel i. Simulation experiments show that when the OFC consists of 35 lines, the measurement range is 0.01–70 GHz, with an error within ±3.24MHz. By adjusting the number of OFC to 51, the measurement range can be expanded to 0.01–102 GHz, while the measurement error of the system remains nearly unchanged. All these results demonstrate that the proposed approach possesses broadband reconfigurability.Keywords
Funding Information
- National Natural Science Foundation of China (62162034)
- Yunnan Fundamental Research Projects (202201AT070189)
This publication has 24 references indexed in Scilit:
- Microwave Photonic IFM Receiver With Adjustable Measurement Range Based on a Dual-Output Sagnac LoopJournal of Lightwave Technology, 2023
- Low Error and Broadband Microwave Frequency Measurement Using a Silicon Mach–Zehnder Interferometer Coupled Ring ArrayJournal of Lightwave Technology, 2023
- Ultra-wideband instantaneous frequency measurement based on differential photonic time-stretchOptics Communications, 2023
- Simultaneous Angle-of-Arrival and Frequency Measurement System Based on Microwave PhotonicsJournal of Lightwave Technology, 2023
- Instantaneous Frequency Measurement With Full FSR Range and Optimized Estimation ErrorJournal of Lightwave Technology, 2022
- Photonic Microwave Frequency Measurement With High Accuracy and Sub-MHz ResolutionJournal of Lightwave Technology, 2022
- Wideband and Ambiguous-Free RF Channelizer Assisted Jointly by Spacing and Profile of Optical Frequency CombIEEE Photonics Journal, 2020
- Measurement of Instantaneous Microwave Frequency by Optical Power Monitoring Based on Polarization InterferenceJournal of Lightwave Technology, 2020
- Photonic Multiple Frequency Measurement Using a Frequency Shifting Recirculating Delay Line StructureJournal of Lightwave Technology, 2014
- A Reconfigurable Microwave Photonic Channelized Receiver Based on Dense Wavelength Division Multiplexing Using an Optical CombOptics Communications, 2012