Evaluation of a novel central venous access port for direct catheter insertion without a peel-away sheath
Open Access
- 17 September 2024
- journal article
- research article
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 43 (2) , 282-289
Abstract
Purpose: This study retrospectively evaluated the feasibility and safety of implanting a newly developed central venous access port (CV-port) that allows catheter insertion into a vein without the use of a peel-away sheath, with a focus on its potential to minimize risks associated with conventional implantation methods. Materials and methods: All procedures were performed using a new device (P-U CelSite Port™ MS; Toray Medical, Tokyo, Japan) under ultrasound guidance. The primary endpoint was the implantation success rate. The secondary endpoints were the safety and risk factors for infection in the early postprocedural period (< 30 days). Results: We assessed 523 CV-port implantations performed in a cumulative total of 523 patients (240 men and 283 women; mean age, 61.6 ± 13.1 years; range, 18–85 years). All implantations were successfully performed using an inner guide tube and over-the-wire technique through 522 internal jugular veins and one subclavian vein. The mean procedural time was 33.2 ± 10.9 min (range 15–112 min). Air embolism, rupture/perforation of the superior vena cava, or hemothorax did not occur during catheter insertion. Eleven (2.1%) intraprocedural complications occurred, including Grade I arrhythmia (n = 8) and subcutaneous bleeding (n = 1), Grade II arrhythmia (n = 1), and Grade IIIa pneumothorax (n = 1). Furthermore, 496 patients were followed up for ≥ 30 days. Six early postprocedural complications were encountered (1.1%), including Grade IIIa infection (n = 4), catheter occlusion (n = 1), and skin necrosis due to subcutaneous leakage of trabectedin (n = 1). These six CV-ports were withdrawn, and no significant risk factors for infection in the early postprocedural period were identified. Conclusion: The implantation of this CV-port device demonstrated comparable success and complication rates to conventional devices, with the added potential benefit of eliminating complications associated with the use of a peel-away sheath.Keywords
This publication has 25 references indexed in Scilit:
- Complication Rates of Central Venous CathetersJAMA Internal Medicine, 2024
- Society of Interventional Radiology Consensus Guidelines for the Periprocedural Management of Thrombotic and Bleeding Risk in Patients Undergoing Percutaneous Image-Guided Interventions—Part II: RecommendationsJournal of Vascular and Interventional Radiology, 2019
- International evidence-based recommendations on ultrasound-guided vascular accessIntensive Care Medicine, 2012
- Venous Access Ports: Indications, Implantation Technique, Follow-Up, and ComplicationsCardioVascular and Interventional Radiology, 2011
- Outcome analysis in 3,160 implantations of radiologically guided placements of totally implantable central venous port systemsEuropean Radiology, 2011
- Quality Improvement Guidelines for Central Venous AccessJournal of Vascular and Interventional Radiology, 2010
- Central venous infusion port inserted via high versus low jugular venous approaches: Retrospective comparison of outcome and complicationsEuropean Journal of Radiology, 2009
- Ultrasonography and fluoroscopy-guided insertion of chest portsEuropean Journal of Surgical Oncology, 2008
- Inadvertent Puncture of the Thoracic Duct During Attempted Central Venous Catheter PlacementCardioVascular and Interventional Radiology, 2003
- Air Embolism during Insertion of Central Venous CathetersJournal of Vascular and Interventional Radiology, 2001