Endoscopic mitral valve repair—one hundred and one ways to use neochords: a narrative review
Authors:
- Faizus SazzadFaizus Sazzad
- Thomas TheologouTTThomas Theologou
- Christos GoutziosCGChristos Goutzios
- Theo KofidisTKTheo Kofidis
Open Access
- 1 September 2025
- journal article
- Published by AME Publishing Company in Journal of Visualized Surgery
- Vol. 11, 24
Abstract
Background and Objective: Mitral valve repair for mitral regurgitation remains technically demanding due to the complex anatomy of the mitral apparatus, including the annulus, left ventricle, papillary muscles, and chordae. Although Alain Carpentier’s “French Correction” laid foundational principles, repair remains challenging, particularly for junior or low-volume surgeons. Neochordal implantation is a critical tool in mitral repair but lacks standardized technique selection, leading to variability in outcomes and surgical training. This narrative review aims to provide a comprehensive classification of neochordal repair techniques and a structured framework to guide clinical application. Methods: A narrative review of published literature on neochordal implantation was conducted, emphasizing technique evolution, anatomical considerations, imaging guidance, and minimally invasive approaches. Over 100 techniques were identified and categorized by anchoring strategy, leaflet involvement, and integration with advanced technologies, including robotic and artificial intelligence (AI)-assisted planning. The review also considers educational tools, simulation methods, and credentialing practices relevant to neochordal repair. Key Content and Findings: Endoscopic mitral valve repair offers patient benefits by avoiding sternotomy but increases technical complexity. Current surgical strategies largely depend on institutional habits, with limited structured guidance. Innovations highlighted include single- and multi-point anchoring, Y-shaped configurations, and techniques optimized using advanced imaging and simulation. These methods allow precise tension distribution, minimize leaflet manipulation, and enhance reproducibility. Despite these advancements, most techniques lack high-level evidence, with data primarily from single-center or retrospective studies. Emerging approaches show promise for biomechanically optimized repairs that simplify complex procedures, potentially reducing mid-term reoperation rates. Training limitations, absence of standardized checklists, and variability in credentialing remain barriers to widespread adoption. Conclusions: Neochordal implantation represents a versatile and evolving component of mitral valve repair. While numerous innovative techniques exist, reproducible outcomes require multicenter validation, long-term follow-up, and standardized training frameworks. This review provides a structured classification of neochordal techniques, identifies emerging trends, and underscores the need for future research and educational standardization to improve surgical consistency and patient outcomes.Keywords
This publication has 56 references indexed in Scilit:
- [Robotic mitral valve repair: perioperative and seven-year follow-up results].2016
- Is minimally invasive mitral valve repair with artificial chords reproducible and applicable in routine surgery?Interactive CardioVascular and Thoracic Surgery, 2015
- Two and three dimensional echocardiography for pre-operative assessment of mitral valve regurgitationCardiovascular Ultrasound, 2014
- Dynamic evaluation of the loop technique using the U-ClipAsian Cardiovascular and Thoracic Annals, 2013
- Significance of force transfer in mitral valve–left ventricular interaction: In vivo assessmentThe Journal of Thoracic and Cardiovascular Surgery, 2013
- A Step toward Nonrobotic Total Endoscopic Coronary Bypass Grafting: 40 Coronary Anastomoses in a Biomechanical Beating Heart ModelInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2012
- Current concepts in mitral valve prolapse—Diagnosis and managementJournal of Cardiology, 2010
- Robotic minimally invasive mitral valve reconstruction yields less blood product transfusion and shorter length of staySurgery, 2006
- Papillary muscle misalignment causes multiple mitral regurgitant jets: an ambiguous mechanism for functional mitral regurgitation.1999
- Durability of mitral valve repair for degenerative diseaseThe Journal of Thoracic and Cardiovascular Surgery, 1998