Arteriovenous fistula creation with VasQTM device: A feasibility study to reveal hemodynamic implications
Open Access
- 22 April 2022
- journal article
- research article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 25 (1) , 60-70
Abstract
Background: Arteriovenous fistula (AVF) is the preferred vascular access (VA) for hemodialysis, but it is still affected by high non-maturation and early failure rates due to stenosis development. Increasing evidence suggests that the presence of turbulent-like flow may play a key role, therefore, to stabilize the flow in the venous segment, an external support device (VasQTM) has been designed. The aim of this study was to provide preliminary evidence of VasQTM impact on AVF hemodynamics as compared to AVFs created with conventional surgery. Methods: In this pilot single-center prospective randomized study six patients were enrolled, three in the VasQ group and three in the control group. Contrast-free magnetic resonance imaging (MRI) scans were acquired at 3 days, 3 months and 1 year after AVF surgery and were used to generate 3D patient-specific models. Computational fluid dynamic (CFD) simulations were performed using pimpleFoam, imposing patient-specific flow waveforms derived from ultrasound (US) examinations at the inlet of the proximal and distal artery, and a traction-free condition at the venous outflow. Morphologic and hemodynamic changes occurring over time were compared between VasQ and control AVFs. Results: Our MRI protocol provided high-quality images suitable for reliable segmentation and reconstruction of patient-specific 3D models of AVFs at all three timepoints in four out of six patients. The VasQTM device maintained the angle between the artery and the vein almost unchanged over time, with a more stable flow in the AVFs supported by the device. In contrast, one of the AVFs of the control group evolved to an extreme dilatation of the vein and highly disturbed flow, while the other developed a stenosis in the juxta-anastomotic region. Conclusions: This study demonstrated the feasibility of characterizing the morphological and hemodynamic changes occurring over time in AVFs created using the VasQTM device and provided preliminary evidence of the potential hemodynamic benefits of its use.Keywords
This publication has 22 references indexed in Scilit:
- Hemodialysis Catheter-related Infection: Prophylaxis, Diagnosis and TreatmentThe Journal of Vascular Access, 2015
- Vascular Access Choice in Incident Hemodialysis PatientsJournal of the American Society of Nephrology, 2015
- Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistulaBiomechanics and Modeling in Mechanobiology, 2013
- Vascular Remodeling in Autogenous Arterio-Venous Fistulas by MRI and CFDAnnals of Biomedical Engineering, 2012
- Effect of anastomosis angle on the localization of disturbed flow in ‘side-to-end’ fistulae for haemodialysis accessNephrology Dialysis Transplantation, 2012
- Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis: low and oscillating shear stress locates the sites of stenosisNephrology Dialysis Transplantation, 2011
- An image-based modeling framework for patient-specific computational hemodynamicsMedical & Biological Engineering & Computing, 2008
- Frequency of Swing-Segment Stenosis in Referred Dialysis Patients With Angiographically Documented LesionsAmerican Journal of Kidney Diseases, 2008
- The relationship between the flow of arteriovenous fistula and cardiac output in haemodialysis patientsNephrology Dialysis Transplantation, 2007
- Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress.Arteriosclerosis: An Official Journal of the American Heart Association, Inc., 1985