Heating and humidifying of carbon dioxide during pneumoperitoneum is not indicated
- 7 December 2005
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 20 (1) , 153-158
Abstract
Carbon dioxide (CO2) pneumoperitoneum usually is created by a compressed gas source. This exposes the patient to cool dry gas delivered at room temperature (21°C) with 0% relative humidity. Various delivery methods are available for humidifying and heating CO2 gas. This study was designed to determine the effects of heating and humidifying gas for the intraabdominal environment. For this study, 44 patients undergoing laparoscopic Roux-en-Y gastric bypass were randomly assigned to one of four arms in a prospective, randomized, single-blinded fashion: raw CO2 (group 1), heated CO2 (group 2), humidified CO2 (group 3), and heated and humidified CO2 (group 4). A commercially available CO2 heater–humidifier was used. Core temperatures, intraabdominal humidity, perioperative data, and postoperative outcomes were monitored. Peritoneal biopsies were taken in each group at the beginning and end of the case. Biopsies were subjected staining protocols designed to identify structural damage and macrophage activity. Postoperative narcotic use, pain scale scores, recovery room time, and length of hospital stay were recorded. One-way analysis of variance (ANOVA) and the nonparametric Kruskal–Wallis test were used to compare the groups. Demographics, volume of CO2 used, intraabdominal humidity, bladder temperatures, lens fogging, and operative times were not significantly different between the groups. Core temperatures were stable, and intraabdominal humidity measurements approached 100% for all the patients over the entire procedure. Total narcotic dosage and pain scale scores were not statistically different. Recovery room times and length of hospital stay were similar in all the groups. Only one biopsy in the heated–humidified group showed an increase in macrophage activity. The intraabdominal environment in terms of temperature and humidity was similar in all the groups. There was no significant difference in the intraoperative body temperatures or the postoperative variable measured. No histologic changes were identified. Heating or humidifying of CO2 is not justified for patients undergoing laparoscopic bariatric surgery.Keywords
This publication has 28 references indexed in Scilit:
- Impact of Temperature and Humidity of Carbon Dioxide Pneumoperitoneum on Body Temperature and Peritoneal MorphologyJournal of Laparoendoscopic & Advanced Surgical Techniques, 2002
- The European Association for Endoscopic Surgery clinical practice guideline on the pneumoperitoneum for laparoscopic surgerySurgical Endoscopy, 2002
- Effect of heated and humidified carbon dioxide gas on core temperature and postoperative painSurgical Endoscopy, 2002
- Effect of CO2 gas warming on pain after laparoscopic surgerySurgical Endoscopy, 1999
- Quantification of Insensible Water Loss Associated with Insufflation of Nonhumidified CO 2 in Patients Undergoing Laparoscopic SurgeryJournal of Laparoendoscopic & Advanced Surgical Techniques, 1999
- Correction of Laparoscopic Insufflation HypothermiaJournal of Laparoendoscopic Surgery, 1991
- The Effects of Airway Heat Conservation and Skin Surface Insulation on Thermal Balance during Spinal SurgeryAnesthesiology, 1988
- The Thermoregulatory Threshold in Humans during Nitrous Oxide-Fentanyl AnesthesiaAnesthesiology, 1988
- Correlations of serum potassium fluctuations with body temperature after major surgeryCritical Care Medicine, 1987
- Influence of Ambient Temperature on Patient Temperature During Intraabdominal SurgeryAnnals of Surgery, 1971