Actuator fault isolation and reconfiguration in transport‐reaction processes
- 7 May 2007
- journal article
- research article
- Published by Wiley in AIChE Journal
- Vol. 53 (6) , 1518-1537
Abstract
A methodology is presented for the design of integrated, model‐based fault diagnosis and reconfigurable control systems for transport‐reaction processes modeled by nonlinear parabolic partial differential equations (PDEs) with control constraints and actuator faults. The methodology brings together nonlinear feedback control, fault detection and isolation (FDI), and performance‐based supervisory switching between multiple actuator configurations. Using an approximate, finite‐dimensional model that captures the PDE's dominant dynamic modes, a stabilizing nonlinear feedback controller is initially designed for each actuator configuration, and its stability region is explicitly characterized in terms of the control constraints and actuator locations. To facilitate the fault diagnosis task, the locations of the control actuators are chosen in a way that ensures that the evolution of each dominant mode, in appropriately chosen coordinates, is excited by only one actuator. Then, a set of dedicated FDI filters, each replicating the fault‐free behavior of a given state of the approximate system, are constructed. The choice of actuator locations ensures that the residual of each filter is sensitive to faults in only one actuator and decoupled from the rest, thus, allowing complete fault isolation. Finally, a set of switching rules are derived to orchestrate switching from the faulty actuators to healthy fallbacks in a way that preserves closed‐loop stability and minimizes the closed‐loop performance deterioration resulting from actuator faults. Precise FDI thresholds and control reconfiguration criteria that account for model reduction errors are derived to prevent false alarms when the reduced order model‐based fault‐tolerant control structure is implemented on the process. A singular perturbation formulation is used to link these thresholds with the degree of separation between the slow and fast eigenvalues of the spatial differential operator. The developed methodology is successfully applied to the problem of constrained, actuator fault‐tolerant stabilization of an unstable steady‐state of a representative diffusion‐reaction process. © 2007 American Institute of Chemical Engineers AIChE J, 2007Keywords
This publication has 45 references indexed in Scilit:
- Integrated Fault Detection and Fault-Tolerant Control Architectures for Distributed ProcessesIndustrial & Engineering Chemistry Research, 2006
- Adaptive Fault-Tolerant Control of Nonlinear Uncertain Systems: An Information-Based Diagnostic ApproachIEEE Transactions on Automatic Control, 2004
- Hybrid predictive control of nonlinear systems: method and applications to chemical processesInternational Journal of Robust and Nonlinear Control, 2003
- Closed‐loop Fault Detection Using the Local ApproachThe Canadian Journal of Chemical Engineering, 2003
- State observation and adaptive linearizing control for distributed parameter (bio)chemical reactorsInternational Journal of Adaptive Control and Signal Processing, 2001
- A geometric approach to nonlinear fault detection and isolationIEEE Transactions on Automatic Control, 2001
- Detection of abrupt changes of total least squares models and application in fault detectionIEEE Transactions on Control Systems Technology, 2001
- Statistical monitoring of multivariable dynamic processes with state‐space modelsAIChE Journal, 1997
- Gross error detection when variance‐covariance matrices are unknownAIChE Journal, 1993
- Actuator failure detection in the control of distributed systemsJournal of Guidance, Control, and Dynamics, 1986