Different approaches to synovial membrane volume determination by magnetic resonance imaging: manual versus automated segmentation
Author:
Open Access
- 1 November 1997
- journal article
- research article
- Published by Oxford University Press (OUP) in Rheumatology
- Vol. 36 (11) , 1166-1177
Abstract
Automated fast (5-20 min) synovial membrane volume determination by MRI, based on pre-set post-gadolinium-DTPA enhancement thresholds, was evaluated as a substitute for a time-consuming (45-120 min), previously validated, manual segmentation method. Twenty-nine knees [rheumatoid arthritis (RA) 13, osteoarthritis (OA) 16] and 17 RA wrists were examined. At enhancement thresholds between 30 and 60%, the automated volumes (Syn(x%)) were highly significantly correlated to manual volumes (SynMan) (knees: rho = 0.78-0.91, P < 10(-5) to < 10(-9); wrists: rho = 0.87-0.95, P < 10(-4) to < 10(-6)). The absolute values of the automated estimates were extremely dependent on the threshold chosen. At the optimal threshold of 45%, the median numerical difference from SynMan was 7 ml (17%) in knees and 2 ml (25%) in wrists. At this threshold, the difference was not related to diagnosis, clinical inflammation or synovial membrane volume, e.g. no systematic errors were found. The inter-MRI variation, evaluated in three knees and three wrists, was higher than by manual segmentation, particularly due to sensitivity to malalignment artefacts. Examination of test objects proved the high accuracy of the general methodology for volume determinations (maximal error 6.3%). Preceded by the determination of reproducibility and the optimal threshold at the available MR unit, automated 'threshold' segmentation appears to be acceptable when changes rather than absolute values of synovial membrane volumes are most important, e.g. in clinical trials.Keywords
This publication has 9 references indexed in Scilit:
- Use of magnetic resonance imaging and positron emission tomography in the assessment of synovial volume and glucose metabolism in patients with rheumatoid arthritisArthritis & Rheumatism, 1995
- Effect of Intraarticular Osmic Acid on Synovial Membrane Volume and Inflammation, Determined by Magnetic Resonance ImagingScandinavian Journal of Rheumatology, 1995
- MR imaging of the arthritic knee: improved discrimination of cartilage, synovium, and effusion with pulsed saturation transfer and fat-suppressed T1-weighted sequences.Radiology, 1994
- Magnetic resonance methods for measurement of disease progression in rheumatoid arthritisMagnetic Resonance Imaging, 1993
- Intraarticular diffusion of Gd-DOTA after intravenous injection in the knee: MR imaging evaluation.Radiology, 1993
- Enhancement of joint fluid with intravenously administered gadopentetate dimeglumine: technique, rationale, and implications.Radiology, 1993
- Juvenile rheumatoid arthritis of the knee: MR evaluation with Gd-DOTA.Radiology, 1992
- Common disorders of synovium-lined joints: pathogenesis, imaging abnormalities, and complicationsAmerican Journal of Roentgenology, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986